The Siemens 5SV4612-0RC is a SENTRON 5SV4 residual current operated circuit breaker (RCCB) designed for single-phase AC electrical networks requiring residual-current protection. It is a 2-pole / 1+N RCCB with a 25 A rated current, 300 mA residual operating current, and Type AC residual-current characteristic. Siemens lists the device as an instantaneous RCCB with a 10 kA short-circuit current rating and 240/415 V AC supply range.
The 5SV4612-0RC belongs to the Siemens SENTRON 5SV4 RCCB family. Its main function is to disconnect the protected circuit when a residual current reaches the specified operating threshold.
The 2-pole configuration is intended for 1-phase + neutral (1+N) installations, making it suitable for residential, commercial and compatible industrial single-phase circuits. Siemens' 2025 residual-current protection catalogue lists the 25 A, 300 mA article within the Type AC, 1P+N, 2-module range.
The RCCB has a rated current of 25 A.
This makes it suitable for compatible single-phase circuits and distribution feeders where a 25 A residual-current protection device is required.
The complete circuit should be designed so that the RCCB is operated within its specified voltage, current and installation conditions.
The 5SV4612-0RC has a rated residual operating current of 300 mA.
When the residual current reaches the specified trip threshold, the device disconnects the protected circuit.
The correct residual-current sensitivity should be selected according to the electrical protection design and applicable installation requirements.
This model is a Type AC RCCB.
Type AC RCCBs are intended for sinusoidal AC residual currents. The appropriate RCCB type should be selected according to the waveform of residual current that may occur in the actual application.
The device has 2 poles and is intended for 1+N single-phase circuits.
This arrangement allows the phase and neutral conductors to be incorporated into the RCCB switching arrangement.
Typical applications include:
Single-phase distribution boards
Residential circuits
Commercial electrical panels
Small industrial feeders
Control circuits
Equipment supply circuits
Sub-distribution systems
The India-facing product description identifies the device as a 240 V, 2-module RCCB. Siemens' current technical data specifies a 240/415 V AC supply-voltage range for the article family, with the 1+N device intended for the appropriate single-phase application.
The actual system voltage should be verified against the installation requirements before selection.
The 5SV4612-0RC is specified as an instantaneous residual-current circuit breaker.
Siemens states that the device does not have a short-time delayed switching function.
This allows the RCCB to respond without an intentional delay when the residual-current threshold is reached.
The device is specified with a 10 kA short-circuit current rating.
The RCCB should still be coordinated with appropriate upstream overcurrent protection and the prospective short-circuit conditions of the electrical installation.
An RCCB provides residual-current protection and should not be treated as a substitute for an overcurrent protective device unless the complete protection scheme specifically provides the required function.
The 5SV4612-0RC has a specified rated insulation voltage of 2,000 V.
This is an important insulation characteristic when integrating the RCCB into the electrical distribution system.
Siemens identifies the device as size 1 according to DIN 43880, corresponding to a compact modular installation format.
For the India product description, the article is specified as 2MW, or 2 module width, making it suitable for compact distribution boards and modular electrical panels.
The Siemens data sheet specifies a 60 mm grid spacing for the device.
This supports integration into conventional modular distribution-board arrangements.
Siemens specifies IP20 protection when the device is installed in a suitable distribution board with connected conductors.
The RCCB should therefore be installed inside an appropriate enclosure or distribution assembly.
A residual current occurs when some current flows through an unintended path, such as leakage to earth.
The RCCB continuously monitors the relevant current balance and trips when the residual current reaches the configured 300 mA operating threshold.
This provides a layer of protection against persistent earth-leakage conditions in the protected circuit.
The 5SV4612-0RC is suitable for compatible single-phase + neutral circuits such as:
Distribution boards
Small power circuits
Commercial installations
Residential electrical systems
Office electrical circuits
Lighting or equipment feeders
Compatible industrial auxiliary circuits
The actual protection application should be determined by the electrical design and applicable regulations.
The compact 2-module form factor makes the device suitable for:
Consumer distribution boards
Commercial panels
Sub-distribution boards
Control panels
Small electrical enclosures
Modular protection assemblies
Its compact design can help optimize available panel space.
Residual-current circuit breakers should be included in an appropriate inspection and testing program.
The RCCB's test function should be operated according to the manufacturer instructions and applicable electrical-maintenance requirements to verify correct tripping operation.
Before selecting the 5SV4612-0RC, verify:
Rated current: 25 A
Residual-current sensitivity: 300 mA
RCCB type: Type AC
Pole arrangement: 2-pole / 1+N
System voltage compatibility
Upstream overcurrent protection
Available panel space
Applicable national installation regulations
Siemens notes that use of these devices is not permitted in all countries and that national installation regulations must be observed.
The 5SV4312-0RC belongs to the same general 25 A, 2-pole Type AC family but uses a 30 mA residual-current sensitivity, whereas 5SV4612-0RC uses 300 mA.
Therefore:
5SV4312-0RC → 30 mA
5SV4612-0RC → 300 mA
The correct sensitivity should be selected according to the intended protection scheme. Siemens' 2025 catalogue lists both sensitivity classes within the Type AC 1P+N family.
The 5SV4412-0 is the corresponding 25 A, 2-pole Type AC, 100 mA version, while 5SV4612-0 is the 300 mA version. Siemens' selection table distinguishes the variants by residual operating current.
The 5SV4642-0RC is a 25 A, 4-pole / 3+N, 300 mA, Type AC RCCB for three-phase plus neutral systems. The 5SV4612-0RC is the 2-pole / 1+N single-phase version. Siemens India lists the 4-pole article separately.
Therefore:
5SV4612-0RC → 25 A, 2-pole, 1+N
5SV4642-0RC → 25 A, 4-pole, 3+N
For installations requiring a higher current rating, Siemens offers other 5SV4 variants such as 40 A Type AC RCCBs.
The 5SV4612-0RC should be selected specifically where the circuit requires a 25 A rated RCCB.
The Siemens 5SV4612-0RC is relevant for:
Electrical panel builders
Industrial buyers
Electrical contractors
Commercial electrical contractors
Facility-maintenance teams
OEMs
Machine builders
Electrical distributors
Electrical product dealers
Maintenance departments
For SB Smart, the product is positioned as a Siemens SENTRON 5SV4 Type AC RCCB for 25 A single-phase residual-current protection.
Siemens SENTRON 5SV4 RCCB
Article number 5SV4612-0RC
25 A rated current
2-pole / 1+N
300 mA residual-current sensitivity
Type AC
Instantaneous operation
10 kA short-circuit current rating
2,000 V rated insulation voltage
240/415 V AC specified supply range
2-module India market format
60 mm grid spacing
IP20 protection when installed in suitable distribution-board conditions
Suitable for single-phase residual-current protection
25 A rating: Suitable for compatible single-phase distribution circuits.
300 mA sensitivity: Provides residual-current protection at the specified operating threshold.
2-pole / 1+N design: Suitable for phase-and-neutral single-phase systems.
Type AC: Designed for compatible AC residual currents.
Instantaneous operation: Provides rapid response without intentional short-time delay.
10 kA short-circuit rating: Supports coordination with suitable upstream protection.
Compact 2-module format: Helps save space in modular distribution boards.
SENTRON design: Provides a standardized Siemens solution for residual-current protection.
The Siemens 5SV4612-0RC is a compact 25 A, 2-pole / 1+N, Type AC RCCB with 300 mA residual-current sensitivity for suitable single-phase AC installations. Siemens specifies the article as an instantaneous 5SV4 RCCB with a 10 kA short-circuit current rating and 2,000 V rated insulation voltage.
It is suitable for customers looking to buy or source Siemens SENTRON 5SV4 RCCBs for single-phase distribution boards, commercial installations, electrical panels and compatible industrial circuits in India.
For SB Smart, this product is best presented as a Siemens Betagard/SENTRON 5SV4 residual-current circuit breaker for 25 A single-phase electrical protection across India.
SB Smart supplies Siemens SENTRON protection devices and industrial electrical products across Faridabad, Gurgaon/Gurugram, Delhi NCR, Haryana, Noida, Punjab, Mumbai and other major Indian cities.
Major delivery locations include:
Faridabad
Delhi
Gurgaon/Gurugram
Delhi NCR
Noida
Greater Noida
Haryana
Punjab
Mumbai
Pune
Ahmedabad
Bengaluru
Hyderabad
Chennai
Kolkata
Jaipur
Chandigarh
Lucknow
Indore
Surat
Vadodara
Nagpur
Coimbatore
And other major cities across India
The 5SV4612-0RC is a Siemens SENTRON 5SV4 residual-current operated circuit breaker rated at 25 A, with 2 poles / 1+N, 300 mA residual-current sensitivity and Type AC characteristics.
It has 2 poles, configured for 1+N single-phase applications.
The rated current is 25 A.
The rated residual operating current is 300 mA.
It is a Type AC RCCB intended for compatible AC residual currents.
Yes. Siemens identifies the device as instantaneous, without short-time delayed switching.
The specified short-circuit current rating is 10 kA.
The India product description identifies the device as a 240 V, 2-module RCCB, while Siemens technical data specifies 240/415 V AC for the supply-voltage range.
For this India product description, 2MW means 2 module width in the modular installation format; it does not mean 2 MW power capacity. The Siemens catalogue identifies this as a 2-pole, size-1 DIN 43880 device.
5SV4612-0RC: 25 A, 2-pole / 1+N, 300 mA, Type AC.
5SV4642-0RC: 25 A, 4-pole / 3+N, 300 mA, Type AC.
No. It is an RCCB. It provides residual-current protection but does not by itself combine residual-current and overcurrent protection like an RCBO.
SB Smart supplies Siemens SENTRON 5SV4 RCCBs and industrial electrical protection products in India for panel builders, electrical contractors, industrial buyers, commercial installations and maintenance requirements.
| Parameter | Specification |
|---|---|
| Product Series | Siemens SENTRON 5SV |
| Part Number | 5SV4612-0RC |
| Product Type | RCCB (Residual Current Circuit Breaker) |
| Number of Poles | 2 Pole (1P+N) |
| Rated Current (In) | 25A |
| Residual Current (IΔn) | 300mA |
| Rated Voltage | 230V AC |
| Type | Type AC |
| Mounting Type | DIN Rail |
| Frequency | 50/60 Hz |
| Application | Earth leakage / fire protection |
No reviews yet.