RES.CUR.OP.CIRCUIT BREAKER TYPE AC 63A 1+N-POLE 30MA 240V 2MW INDIA - 5SV4316-0RC

(0 Reviews)
Best Price (Excl. GST):
3,012 / nos MRP: ₹8,605 / nos
GST (18%): 542
Total Price (Incl. GST): ₹3,554
You Save: ₹5,593 (65%)
Ready to Dispatch
Quantity:
nos
Secure
Fast Delivery
24/7 Support

100% Genuine Product

Industrial Grade

Quality Tested

GST Invoice Available

Product Description


Siemens 5SV4316-0RC RCCB – 63A, 2-Pole, 30mA, Type AC, 240V

The Siemens 5SV4316-0RC is a SENTRON 5SV4 Residual Current Operated Circuit Breaker (RCCB) designed for residual-current protection in suitable single-phase AC electrical installations. It is a 2-pole / 1+N, Type AC RCCB with a 63 A rated current and 30 mA rated residual operating current. Siemens technical documentation identifies the corresponding 5SV4316-0 as an instantaneous 2-pole Type AC RCCB with 63 A, 30 mA and 230 V AC ratings.

The India-facing product designation specifies 240 V, 2MW, making this model suitable for compatible single-phase distribution and protection applications.

Siemens 5SV4316-0RC Residual Current Circuit Breaker

The 5SV4316-0RC belongs to the Siemens SENTRON 5SV4 RCCB family. Its primary function is to detect residual current in a protected circuit and disconnect the circuit when the residual current reaches the specified operating threshold.

The 2-pole / 1+N configuration is intended for single-phase circuits where phase and neutral are incorporated into the residual-current protection arrangement.

63 A Rated Current

The RCCB has a rated current of 63 A.

This makes it suitable for compatible single-phase distribution circuits and feeders where a 63 A residual-current protection device is required.

The connected circuit should be designed so that the RCCB operates within its specified current, voltage and installation conditions.

30 mA Residual Current Sensitivity

The 5SV4316-0RC has a rated residual operating current of 30 mA. Siemens' current datasheet confirms the 30 mA tripping fault current for the corresponding 5SV4316-0 article.

When residual current reaches the specified operating threshold, the RCCB trips and disconnects the protected circuit.

The 30 mA sensitivity should be selected according to the overall electrical protection design and applicable installation requirements.

Type AC Residual Current Protection

The device is a Type AC RCCB.

Type AC residual-current circuit breakers are intended for compatible sinusoidal alternating residual currents. The correct RCCB type should be selected according to the leakage-current waveform that may occur in the actual installation.

2-Pole / 1+N Configuration

The 5SV4316-0RC has 2 poles and is designed for 1+N single-phase applications.

This arrangement allows the phase and neutral conductors to be incorporated into the residual-current protection system.

Typical applications include:

  • Single-phase distribution boards

  • Commercial electrical panels

  • Sub-distribution circuits

  • Equipment feeders

  • Building electrical installations

  • Industrial auxiliary circuits

  • Single-phase feeder protection

240 V AC / 230 V AC Application

The supplied India product description identifies the device as a 240 V, 2-module RCCB. Siemens' current datasheet for the corresponding 5SV4316-0 specifies 230 V AC rated supply voltage.

For the SB Smart product page, the 240 V India-market designation can be retained while the exact Siemens technical rating should be considered when selecting the device for an installation.

Instantaneous Operation

The 5SV4316-0RC is an instantaneous RCCB. Siemens specifies that its switching function is not short-time delayed.

This means the device responds without an intentionally introduced short-time delay when the specified residual-current threshold is reached.

10 kA Short-Circuit Current Rating

Siemens specifies a 10 kA short-circuit current rating for the corresponding 5SV4316-0 article.

The RCCB should nevertheless be coordinated with suitable upstream overcurrent protection and the prospective short-circuit conditions of the installation.

An RCCB primarily provides residual-current protection and should not be treated as a substitute for an MCB or MCCB for overload and short-circuit protection unless the complete protection arrangement specifically provides those functions.

Compact Modular Design

The India product description specifies 2MW, meaning 2 module width.

The 2MW designation refers to the physical modular width and does not indicate a 2 MW power rating. The older Siemens short-form catalogue also identifies the 63 A 2-pole Type AC 30 mA model within the compact modular range.

This compact format is suitable for:

  • Modular distribution boards

  • Consumer units

  • Commercial panels

  • Sub-distribution boards

  • Compact electrical enclosures

DIN Modular Installation

The 5SV4316-0RC is designed for installation in suitable modular electrical distribution assemblies.

The corresponding Siemens device is classified as size 1 according to DIN 43880 and uses a 60 mm grid spacing.

This supports integration with conventional modular protection equipment.

Residual Current Protection

Residual current occurs when part of the electrical current flows outside the intended circuit path, such as through an unintended earth-leakage route.

The RCCB monitors the relevant current balance and disconnects the protected circuit when the residual current reaches the configured 30 mA threshold.

This provides an important additional layer of residual-current protection.

Single-Phase Distribution Applications

The 5SV4316-0RC can be considered for compatible single-phase applications such as:

  • Residential distribution boards

  • Commercial electrical panels

  • Building sub-distribution systems

  • Equipment supply circuits

  • Office electrical installations

  • Single-phase feeder protection

  • Industrial auxiliary circuits

The actual protection application should be determined by the electrical design and applicable regulations.

Protection Coordination

An RCCB should be coordinated with suitable overcurrent protection where required.

A typical arrangement may include:

Incoming Supply → MCB/MCCB → RCCB → Protected Load

The exact arrangement depends on the electrical system, upstream protection and installation requirements.

The RCCB's residual-current function should be considered separately from overload and short-circuit protection.

Maintenance and Testing

RCCBs should be included in an appropriate electrical inspection and testing program.

The test function should be operated according to the manufacturer's instructions and applicable maintenance requirements to verify correct residual-current tripping.

Regular testing can help confirm that the protective mechanism remains operational.

Installation Considerations

Before selecting the 5SV4316-0RC, verify:

  • Rated current: 63 A

  • Residual-current sensitivity: 30 mA

  • RCCB type: Type AC

  • Pole arrangement: 2-pole / 1+N

  • System voltage compatibility

  • Upstream overcurrent protection

  • Available panel space: 2 module width

  • Conductor size and termination

  • Applicable national electrical regulations

Siemens explicitly notes that these devices are not permitted in all countries and that national installation regulations must be observed.

Difference from 25 A Version

The 5SV4312-0 is the corresponding 25 A, 2-pole / 1+N, 30 mA, Type AC RCCB, while 5SV4316-0 is rated at 63 A. Siemens product-selection data lists both within the Type AC 1P+N family.

Therefore:

5SV4312-0RC → 25 A, 30 mA

5SV4316-0RC → 63 A, 30 mA

Difference from 40 A Version

The 5SV4314-0 is the corresponding 40 A, 2-pole / 1+N, 30 mA, Type AC version.

Therefore:

5SV4314-0RC → 40 A

5SV4316-0RC → 63 A

The main difference is the rated current of the protected circuit.

Difference from 80 A Version

The 5SV4317-0 is the corresponding 80 A, 2-pole / 1+N, 30 mA, Type AC version. Siemens' catalogue lists the 63 A and 80 A variants together in this family.

Therefore:

5SV4316-0RC → 63 A

5SV4317-0RC → 80 A

Difference from 100 mA Version

The 5SV4416-0RC is the corresponding 63 A, 2-pole / 1+N, Type AC, 100 mA version.

Therefore:

5SV4316-0RC → 63 A, 30 mA

5SV4416-0RC → 63 A, 100 mA

The principal difference is the residual-current operating threshold. Siemens' product selection distinguishes these variants by residual-current sensitivity.

Difference from 300 mA Version

The 5SV4616-0RC is the corresponding 63 A, 2-pole / 1+N, Type AC, 300 mA version.

Therefore:

5SV4316-0RC → 63 A, 30 mA

5SV4416-0RC → 63 A, 100 mA

5SV4616-0RC → 63 A, 300 mA

The correct residual-current sensitivity should be selected according to the electrical protection scheme.

Difference from 4-Pole Version

The 5SV4346-0RC is a 63 A, 4-pole / 3+N, Type AC, 30 mA RCCB, whereas the 5SV4316-0RC is a 63 A, 2-pole / 1+N device.

Therefore:

5SV4316-0RC → 63 A, 2-pole / 1+N

5SV4346-0RC → 63 A, 4-pole / 3+N

The first is intended for suitable single-phase circuits, while the second is for suitable three-phase-plus-neutral systems.

Suitable for Electrical Panel Builders and Industrial Buyers

The Siemens 5SV4316-0RC is relevant for:

  • Electrical panel builders

  • Industrial buyers

  • Electrical contractors

  • Commercial electrical contractors

  • Facility-maintenance teams

  • OEMs

  • Machine builders

  • Electrical distributors

  • Industrial maintenance departments

  • Electrical product dealers

For SB Smart, the product is positioned as a Siemens Betagard/SENTRON 5SV4 Type AC RCCB for 63 A single-phase residual-current protection.

Technical Specification

SpecificationDetails
BrandSiemens
Product FamilySENTRON / Betagard 5SV4
Article Number5SV4316-0RC
Product TypeResidual Current Operated Circuit Breaker (RCCB)
RCCB TypeType AC
Rated Current63 A
Number of Poles2 Pole / 1+N
Residual Operating Current30 mA
OperationInstantaneous
Rated Operating Voltage230 V AC for corresponding Siemens article
India Market Description240 V, 2MW
Module Width2 Modules
DIN SizeSize 1 according to DIN 43880
Grid Spacing60 mm
Short-Circuit Current Rating10 kA
Rated Insulation Voltage2,000 V
Protection DegreeIP20 when installed in a suitable distribution board with connected conductors
Operating Frequency50 Hz

These values are based on Siemens' current datasheet for 5SV4316-0 and related official product data.

Key Features

  • Siemens SENTRON / Betagard 5SV4 RCCB

  • Article number 5SV4316-0RC

  • 63 A rated current

  • 2-pole / 1+N configuration

  • 30 mA residual-current sensitivity

  • Type AC

  • Instantaneous operation

  • 230 V AC rated operating voltage for the corresponding Siemens article

  • 240 V India-market designation

  • 2-module modular format

  • 10 kA short-circuit current rating

  • 2,000 V rated insulation voltage

  • 60 mm grid spacing

  • DIN modular installation

  • Suitable for single-phase residual-current protection

Benefits

  • 63 A rating: Suitable for compatible higher-current single-phase distribution circuits.

  • 30 mA sensitivity: Provides residual-current protection at the specified operating threshold.

  • 2-pole / 1+N design: Suitable for phase-and-neutral single-phase systems.

  • Type AC: Designed for compatible sinusoidal AC residual currents.

  • Instantaneous operation: Provides residual-current disconnection without intentional short-time delay.

  • Compact 2-module format: Helps save space in modular distribution boards.

  • DIN modular installation: Supports convenient integration into standard electrical protection assemblies.

  • 10 kA short-circuit rating: Supports coordination with suitable upstream protective equipment.

  • SENTRON 5SV4 design: Provides a standardized Siemens residual-current protection solution.

Why Choose Siemens 5SV4316-0RC?

The Siemens 5SV4316-0RC is a 63 A, 2-pole / 1+N, Type AC RCCB with 30 mA residual-current sensitivity, designed for suitable single-phase AC installations. Siemens' current datasheet confirms the corresponding 5SV4316-0 as an instantaneous 63 A, 30 mA, 230 V AC RCCB with a 10 kA short-circuit current rating and compact DIN installation format.

It is suitable for customers looking to buy or source Siemens SENTRON/Betagard 5SV4 RCCBs for single-phase distribution boards, commercial electrical panels, building installations and compatible industrial circuits in India.

For SB Smart, this product is best presented as a Siemens 5SV4 residual-current circuit breaker for 63 A single-phase electrical protection across India.

Delivery Across India

SB Smart supplies Siemens SENTRON/Betagard RCCBs and industrial electrical protection products across Faridabad, Gurgaon/Gurugram, Delhi NCR, Haryana, Noida, Punjab, Mumbai and other major Indian cities.

Major delivery locations include:

  • Faridabad

  • Delhi

  • Gurgaon/Gurugram

  • Delhi NCR

  • Noida

  • Greater Noida

  • Haryana

  • Punjab

  • Mumbai

  • Pune

  • Ahmedabad

  • Bengaluru

  • Hyderabad

  • Chennai

  • Kolkata

  • Jaipur

  • Chandigarh

  • Lucknow

  • Indore

  • Surat

  • Vadodara

  • Nagpur

  • Coimbatore

  • And other major cities across India

Frequently Asked Questions

1. What is Siemens 5SV4316-0RC?

The 5SV4316-0RC is a Siemens SENTRON 5SV4 residual-current operated circuit breaker rated at 63 A, with 2 poles / 1+N, 30 mA residual-current sensitivity and Type AC characteristics.

2. How many poles does it have?

It has 2 poles, configured for 1+N single-phase applications.

3. What is the rated current?

The rated current is 63 A.

4. What is the residual-current sensitivity?

The rated residual operating current is 30 mA.

5. What type of RCCB is it?

It is a Type AC RCCB intended for compatible AC residual-current protection.

6. Is it instantaneous?

Yes. Siemens identifies the device as instantaneous, with no short-time delayed switching function.

7. What is the voltage rating?

The current Siemens datasheet specifies 230 V AC for the corresponding 5SV4316-0 article, while the India-facing description uses 240 V.

8. What does 2MW mean?

2MW means 2 module width in the modular installation format. It does not mean a 2 MW power rating.

9. What is the short-circuit current rating?

The specified short-circuit current rating is 10 kA.

10. What is the difference between 5SV4316-0RC and 5SV4416-0RC?

5SV4316-0RC: 63 A, 2-pole / 1+N, Type AC, 30 mA

5SV4416-0RC: 63 A, 2-pole / 1+N, Type AC, 100 mA.

11. What is the difference between 5SV4316-0RC and 5SV4346-0RC?

5SV4316-0RC: 63 A, 2-pole / 1+N, 30 mA.

5SV4346-0RC: 63 A, 4-pole / 3+N, 30 mA.

The first is for suitable single-phase circuits and the second is for suitable three-phase-plus-neutral systems.

12. Where can I buy Siemens 5SV4316-0RC in India?

SB Smart supplies Siemens SENTRON/Betagard 5SV4 RCCBs and industrial electrical protection products in India for panel builders, electrical contractors, industrial buyers, commercial installations and maintenance requirements.

Technical Specifications

ParameterSpecification
Product SeriesSiemens SENTRON 5SV4
Part Number5SV4316-0RC
Product TypeResidual Current Circuit Breaker (RCCB)
Number of Poles1P+N (2 Pole)
Rated Current (In)63A
Residual Operating Current (IΔn)30mA
RCCB TypeType AC
Rated Voltage230/240V AC
Frequency50 Hz
Mounting TypeDIN Rail Mounting
Degree of ProtectionIP20
Short-Circuit Rating10kA
Rated Insulation Voltage (Ui)2000V
Mechanical Life10,000 Operations
Operating Temperature-25°C to +45°C
Standard ComplianceIEC 61008-1
ApplicationEarth Leakage Protection, Distribution Boards, Control Panels

Customer Reviews

Write a Review

No reviews yet.

Why Buy From SB Smart?

Authorized Supplier
Genuine products directly from manufacturers with warranty support.
Industrial Expertise
Over 10 years of experience in industrial automation and electricals.
PAN India Delivery
Fast and secure shipping to all major industrial hubs across India.
Dedicated Support
Expert technical team available for product selection and support.

Request a Quote

×
Product: Product Name

Thank You!

Your quote request has been submitted successfully.

Our team will contact you shortly.

Product Enquiry

×
Enquiring for: Product Name

Enquiry Sent!

We have received your enquiry.

Our team will get back to you soon.