The Siemens 5SV3314-6RC is a SENTRON 5SV3 Residual Current Operated Circuit Breaker (RCCB) designed for residual-current protection in suitable single-phase AC electrical installations. It is a 2-pole / 1+N, Type A RCCB with a 40 A rated current and 30 mA rated residual operating current. Siemens identifies the corresponding 5SV3314-6 as an instantaneous 2-pole Type A RCCB, rated 40 A, 30 mA and 230 V AC.
The supplied India product designation specifies 240 V and 2MW, making this model suitable for compatible single-phase distribution boards, electrical panels and feeder applications.
The 5SV3314-6RC belongs to the Siemens SENTRON 5SV3 RCCB family. Its primary function is to monitor residual current and disconnect the protected circuit when the residual current reaches the specified operating threshold.
The 2-pole / 1+N configuration is intended for suitable single-phase systems where phase and neutral are incorporated into the residual-current protection arrangement.
Siemens currently lists the corresponding 5SV3314-6 as an active product under its SENTRON RCCB range.
The RCCB has a rated current of 40 A.
This makes it suitable for compatible single-phase distribution circuits and feeders where a 40 A residual-current protection device is required.
The protected circuit should be designed so that the RCCB operates within its specified current, voltage and installation conditions.
The 5SV3314-6RC has a rated residual operating current of 30 mA.
When residual current reaches the specified operating threshold, the RCCB trips and disconnects the protected circuit.
The 30 mA sensitivity should be selected according to the complete electrical protection design and applicable installation requirements. Siemens confirms the 30 mA rated tripping fault current for the corresponding article.
The device is a Type A RCCB.
Compared with Type AC devices, Type A RCCBs are designed to detect suitable AC residual currents as well as pulsating DC residual-current components. This makes Type A protection useful for many installations containing modern electronic loads.
Potential applications can include:
Electronic power supplies
Rectifier-based equipment
Automation equipment
Variable-speed equipment
Industrial machinery
Modern commercial electrical equipment
The correct RCCB type should always be selected according to the residual-current characteristics of the connected equipment.
The 5SV3314-6RC has 2 poles and is designed for 1+N single-phase applications.
This arrangement allows the phase and neutral conductors to be incorporated into the residual-current protection system.
Typical applications include:
Single-phase distribution boards
Commercial electrical panels
Building electrical installations
Sub-distribution circuits
Equipment feeders
Office electrical systems
Industrial auxiliary circuits
The supplied India product designation identifies the device as 240 V, 2MW.
Siemens' official technical data for the corresponding 5SV3314-6 specifies 230 V AC rated operating voltage.
For the SB Smart product page, the 240 V India-market designation can be retained, while the exact Siemens technical rating should be considered when selecting the device for an installation.
The 5SV3314-6RC is an instantaneous RCCB. Siemens specifies that the switching function is not short-time delayed.
This means the device responds without an intentionally introduced short-time delay when the specified residual-current threshold is reached.
The corresponding Siemens 5SV3314-6 is specified with a 10 kA short-circuit current rating and a maximum permissible 63 A series fuse for short-circuit protection coordination.
The RCCB should nevertheless be coordinated with suitable upstream overcurrent protection and the prospective short-circuit conditions of the installation.
An RCCB primarily provides residual-current protection and should not be treated as a substitute for an MCB or MCCB for overload and short-circuit protection unless the complete protection arrangement specifically provides those functions.
The India product designation specifies 2MW, meaning 2 module width.
The 2MW designation refers to the physical modular width and does not indicate a 2 MW power rating.
The Siemens Type A 1P+N range is designed in a compact 2-module format.
This format is suitable for:
Modular distribution boards
Consumer units
Commercial electrical panels
Sub-distribution boards
Compact electrical enclosures
The 5SV3314-6RC is designed for modular electrical installation.
Siemens identifies the corresponding device as size 1 according to DIN 43880 with 60 mm grid spacing.
It can therefore be integrated into suitable DIN-type distribution assemblies alongside compatible MCBs, busbars and other protection accessories.
Siemens specifies IP20 protection when the device is installed in a suitable distribution board with connected conductors.
The RCCB should therefore be installed inside an appropriate electrical enclosure or distribution assembly.
Residual current occurs when part of the electrical current flows through an unintended path, such as leakage to earth.
The RCCB monitors the relevant current balance and disconnects the protected circuit when the residual current reaches the configured 30 mA threshold.
This provides an additional layer of residual-current protection within the overall electrical safety system.
The Type A characteristic makes the 5SV3314-6RC suitable for compatible installations where residual currents may include pulsating DC components.
Potential applications include:
Industrial automation equipment
Electronic control panels
Rectifier-based machinery
Variable-speed equipment
Commercial electronic systems
Modern machine installations
Power-electronic loads
The actual suitability should be verified against the residual-current characteristics of the connected equipment.
The 5SV3314-6RC can be considered for compatible single-phase applications such as:
Commercial distribution boards
Building electrical panels
Residential distribution systems
Office electrical circuits
Equipment supply circuits
Single-phase feeder protection
Industrial auxiliary circuits
The final protection application should be determined according to the electrical design and applicable regulations.
An RCCB should be coordinated with suitable overcurrent protection where required.
A typical protection arrangement can be:
Incoming Supply → MCB/MCCB → RCCB → Protected Load
The exact configuration depends on the electrical system, upstream protective device and applicable installation requirements.
The RCCB's residual-current function should be considered separately from overload and short-circuit protection.
RCCBs should be included in an appropriate electrical inspection and testing program.
The test function should be operated according to the manufacturer's instructions and applicable maintenance requirements to verify correct residual-current tripping.
Regular testing can help confirm that the protection mechanism remains operational.
Before selecting the 5SV3314-6RC, verify:
Rated current: 40 A
Residual-current sensitivity: 30 mA
RCCB type: Type A
Pole arrangement: 2-pole / 1+N
System voltage compatibility
Upstream overcurrent protection
Available panel space: 2 module width
Conductor size and termination
Connected equipment leakage-current characteristics
Applicable national electrical regulations
The RCCB type should always be selected according to the actual load and residual-current waveform.
The 5SV4314-0RC is a 40 A, 2-pole, Type AC, 30 mA RCCB, whereas the 5SV3314-6RC is a 40 A, 2-pole, Type A, 30 mA RCCB.
Therefore:
5SV3314-6RC → Type A, 40 A, 30 mA
5SV4314-0RC → Type AC, 40 A, 30 mA
The main difference is the residual-current type.
The 5SV3312-6 is the corresponding 25 A, 2-pole, Type A, 30 mA device.
Therefore:
5SV3312-6 → 25 A
5SV3314-6RC → 40 A
Both use the Type A, 1P+N, 30 mA configuration. Siemens' selection data lists both current ratings in the same range.
The 5SV3316-6 is the corresponding 63 A, 2-pole, Type A, 30 mA device.
Therefore:
5SV3314-6RC → 40 A
5SV3316-6 → 63 A
The primary difference is rated current.
The 5SV3317-6 is the corresponding 80 A, 2-pole, Type A, 30 mA device.
Therefore:
5SV3314-6RC → 40 A
5SV3316-6 → 63 A
5SV3317-6 → 80 A
The 5SV3414-6 is the corresponding 40 A, 2-pole, Type A, 100 mA device.
Therefore:
5SV3314-6RC → 40 A, 30 mA
5SV3414-6 → 40 A, 100 mA
The key difference is the residual-current operating threshold. Siemens' selection table distinguishes the Type A variants by residual-current sensitivity.
The 5SV3614-6 is the corresponding 40 A, 2-pole, Type A, 300 mA device.
Therefore:
5SV3314-6RC → 40 A, 30 mA
5SV3414-6 → 40 A, 100 mA
5SV3614-6 → 40 A, 300 mA
The 5SV3344-6RC is a 40 A, 4-pole / 3+N, Type A, 30 mA RCCB, while the 5SV3314-6RC is a 40 A, 2-pole / 1+N device.
Therefore:
5SV3314-6RC → 40 A, 2-pole / 1+N, Type A, 30 mA
5SV3344-6RC → 40 A, 4-pole / 3+N, Type A, 30 mA
The first is intended for suitable single-phase systems and the second for suitable three-phase-plus-neutral systems.
The Siemens 5SV3314-6RC is relevant for:
Electrical panel builders
Industrial buyers
Electrical contractors
Commercial electrical contractors
Facility-maintenance teams
OEMs
Machine builders
Electrical distributors
Industrial maintenance departments
Electrical product dealers
For SB Smart, the product is positioned as a Siemens SENTRON 5SV3 Type A RCCB for 40 A single-phase residual-current protection.
| Specification | Details |
|---|---|
| Brand | Siemens |
| Product Family | SENTRON 5SV3 |
| Article Number | 5SV3314-6RC |
| Product Type | Residual Current Operated Circuit Breaker (RCCB) |
| RCCB Type | Type A |
| Rated Current | 40 A |
| Number of Poles | 2 Pole / 1+N |
| Residual Operating Current | 30 mA |
| Operation | Instantaneous |
| Rated Operating Voltage | 230 V AC for corresponding Siemens article |
| India Market Description | 240 V, 2MW |
| Module Width | 2 Modules |
| DIN Size | Size 1 according to DIN 43880 |
| Grid Spacing | 60 mm |
| Short-Circuit Current Rating | 10 kA |
| Maximum Series Fuse | 63 A |
| Rated Insulation Voltage | 2,000 V |
| Pollution Degree | 2 |
| Protection Degree | IP20 when installed in a suitable distribution board |
| Switching Capacity per IEC 61008-1 | 0.5 kA |
| Power Loss per Pole | 2.6 W at rated current |
| Typical Mechanical Service Life | 10,000 operating cycles |
| Operating Frequency | 50 Hz |
These specifications are based on Siemens' current technical data for 5SV3314-6.
Siemens SENTRON 5SV3 RCCB
Article number 5SV3314-6RC
40 A rated current
2-pole / 1+N configuration
30 mA residual-current sensitivity
Type A
Instantaneous operation
230 V AC technical rating for the corresponding Siemens article
240 V India-market designation
2-module modular format
10 kA short-circuit current rating
2,000 V rated insulation voltage
60 mm grid spacing
DIN modular installation
Suitable for single-phase residual-current protection
Suitable for installations with compatible electronic loads
Type A protection: Suitable where residual currents may include pulsating DC components.
40 A rating: Suitable for compatible higher-current single-phase circuits.
30 mA sensitivity: Provides residual-current protection at the specified operating threshold.
2-pole / 1+N design: Suitable for phase-and-neutral single-phase systems.
Instantaneous operation: Provides residual-current disconnection without intentional short-time delay.
Compact 2-module format: Helps optimize space in modular distribution boards.
DIN modular installation: Supports convenient integration into standard electrical protection assemblies.
10 kA short-circuit rating: Supports coordination with suitable upstream protective equipment.
SENTRON 5SV3 platform: Provides a Siemens solution for Type A residual-current protection.
The Siemens 5SV3314-6RC is a 40 A, 2-pole / 1+N, Type A RCCB with 30 mA residual-current sensitivity, designed for suitable single-phase AC electrical installations. Siemens' current Industry Mall and data sheet identify the corresponding 5SV3314-6 as an active, instantaneous 2-pole Type A RCCB with 40 A rated current, 30 mA residual current and 230 V AC rated voltage.
Its Type A characteristic makes it particularly suitable for compatible installations where residual currents may contain pulsating DC components.
For SB Smart, this product is best presented as a Siemens SENTRON 5SV3 Type A residual-current circuit breaker for 40 A single-phase electrical protection across India.
SB Smart supplies Siemens SENTRON/Betagard RCCBs and industrial electrical protection products across Faridabad, Gurgaon/Gurugram, Delhi NCR, Haryana, Noida, Punjab, Mumbai and other major Indian cities.
Major delivery locations include:
Faridabad
Delhi
Gurgaon/Gurugram
Delhi NCR
Noida
Greater Noida
Haryana
Punjab
Mumbai
Pune
Ahmedabad
Bengaluru
Hyderabad
Chennai
Kolkata
Jaipur
Chandigarh
Lucknow
Indore
Surat
Vadodara
Nagpur
Coimbatore
And other major cities across India
The 5SV3314-6RC is a Siemens SENTRON 5SV3 residual-current operated circuit breaker rated at 40 A, with 2 poles / 1+N, 30 mA residual-current sensitivity and Type A characteristics.
It has 2 poles, configured for 1+N single-phase applications.
The rated current is 40 A.
The rated residual operating current is 30 mA.
It is a Type A RCCB, suitable for compatible AC residual currents and pulsating DC residual-current components.
Yes. Siemens identifies the corresponding 5SV3314-6 as instantaneous, without short-time delayed switching.
Siemens' current technical data specifies 230 V AC for the corresponding 5SV3314-6 article, while the supplied India description uses 240 V.
2MW means 2 module width in the modular installation format. It does not mean a 2 MW power rating.
The specified short-circuit current rating is 10 kA.
5SV3314-6RC: 40 A, 2-pole / 1+N, Type A, 30 mA.
5SV4314-0RC: 40 A, 2-pole / 1+N, Type AC, 30 mA.
5SV3314-6RC: 40 A, Type A, 30 mA.
5SV3414-6: 40 A, Type A, 100 mA.
SB Smart supplies Siemens SENTRON 5SV3 Type A RCCBs and industrial electrical protection products in India for panel builders, electrical contractors, industrial buyers, maintenance teams and distribution applications.
|
Parameter |
Specification |
|
Product
Series |
Siemens
SENTRON 5SV3 |
|
Part
Number |
5SV3314-6RC |
|
Product
Type |
RCCB
(Residual Current Circuit Breaker) |
|
Type |
Type
A |
|
Rated
Current |
40
A |
|
Sensitivity |
30
mA |
|
Poles |
2
Pole |
|
Rated
Voltage |
230
V AC |
|
Short-Circuit
Capacity |
10
kA |
|
Mounting
Type |
DIN
Rail |
|
Protection |
Earth
leakage (residual current) |
|
Standard |
IEC
61008-1 |
|
Application |
Residential,
Commercial & Light Industrial |