The Siemens 5SU1644-1RC32 is a SENTRON / Betagard 5SU1 Residual Current Circuit Breaker with Overcurrent Protection (RCBO) designed to combine overload, short-circuit and residual-current protection in a single device. The exact product designation is 32 A, 4-pole, 8 modules, C characteristic, Type AC, 300 mA. Siemens documentation includes 5SU1644-1RC32 in the 5SU1 4-pole RCBO range, while Indian product data confirms the specific 32 A, Type AC, 300 mA and C-curve configuration.
The 5SU1644-1RC32 belongs to the Siemens SENTRON / Betagard 5SU1 RCBO family. Unlike a conventional RCCB, an RCBO combines multiple protection functions within one device:
Overload protection
Short-circuit protection
Residual-current protection
This integrated construction can simplify electrical-panel design and provide dedicated protection for a three-phase circuit.
Siemens' documentation lists the exact article 5SU1644-1RC32 within the 4-pole 5SU1 RCBO product family.
The 5SU1644-1RC32 has a rated current of 32 A.
This makes it suitable for compatible three-phase circuits and feeders designed around a 32 A protective device.
The actual selection should consider:
Connected load
Cable ampacity
Installation method
Ambient conditions
Prospective short-circuit current
Protection coordination requirements
Indian product data confirms the 32 A rating for the exact article.
The RCBO uses a C tripping characteristic.
A C-curve device is intended for circuits where normal operation can involve moderate starting or inrush current.
Potential applications include compatible:
Motors
Pumps
Fans
Control transformers
Contactors
Solenoids
Industrial equipment
Selected lighting and electronic loads
The C characteristic should be selected according to the actual load characteristics and protection-coordination requirements.
The 5SU1644-1RC32 uses Type AC residual-current protection.
Type AC devices are intended for compatible sinusoidal alternating residual currents.
The residual-current waveform of the connected equipment should be considered before selecting the protection type. Equipment that produces pulsating DC or other residual-current components may require a different RCCB/RCBO type.
Indian product data confirms the exact article as Type AC.
The RCBO has a rated residual operating current of 300 mA.
When the residual-current condition reaches the applicable operating threshold, the RCBO disconnects the protected circuit.
The 300 mA sensitivity should be selected according to the complete electrical protection design. It should not automatically be replaced with a 30 mA device because the two values serve different protection requirements.
The exact product data confirms 300 mA residual-current sensitivity.
The device has 4 poles, making it suitable for compatible three-phase plus neutral electrical systems.
The four-pole arrangement allows the three phases and neutral to be incorporated into the circuit protection arrangement.
Typical applications include:
Three-phase distribution boards
Industrial feeder circuits
PCC panels
MCC panels
Commercial electrical panels
Machine power circuits
Factory electrical systems
Sub-distribution boards
Indian product information for the exact 32 A article identifies the device for 415 V AC applications, while the product-family technical data uses the relevant IEC low-voltage ratings for the 5SU1 range.
For the SB Smart product page, the 415 V AC market designation can be retained. The actual installation voltage should always be checked against the applicable Siemens technical documentation and electrical-system design.
The exact Indian technical listing identifies the 5SU1644-1RC32 with a 10 kA breaking capacity.
The prospective short-circuit current at the installation point should still be checked during system design, along with upstream protection and coordination requirements.
Since this is an RCBO, the device incorporates overcurrent protection as part of its construction.
The main advantage of the 5SU1644-1RC32 is its integrated protection arrangement.
A conventional installation may use:
MCB + RCCB
An RCBO combines these protective functions:
RCBO = Overload + Short Circuit + Residual Current Protection
This can simplify circuit-level protection and reduce the need for separate overcurrent and residual-current devices.
The supplied product description specifies 8 modules.
The module designation refers to the physical installation space required within a modular electrical panel and does not represent an 8 MW power rating.
The four-pole construction and integrated protection functions make adequate panel space important during installation.
Indian product information identifies the exact article as an 8-module RCBO.
The 5SU1 RCBO family is designed for modular electrical-panel applications.
The 5SU1644-1RC32 can be integrated into appropriately sized:
Distribution boards
Electrical control panels
PCC panels
MCC panels
Industrial switchboards
Commercial electrical enclosures
Machine panels
Panel builders should verify available space and compatibility with the selected installation accessories.
The RCBO's overcurrent section provides protection against sustained excessive current resulting from circuit overload.
The 32 A rating should be coordinated with:
Cable size
Load current
Installation method
Ambient temperature
Protection requirements
This helps ensure proper circuit protection during normal and abnormal operating conditions.
The integrated overcurrent protection also provides short-circuit protection.
The 10 kA breaking capability should be evaluated against the prospective fault current at the installation point.
Correct coordination with the upstream electrical system remains important even though the RCBO incorporates overcurrent protection.
Residual current occurs when a portion of current flows outside its intended electrical path, such as through an unintended leakage path to earth.
The RCBO monitors the residual-current condition and disconnects the protected circuit when the specified 300 mA threshold is reached.
This provides an additional protection function beyond overload and short-circuit protection.
The C characteristic is suitable for selected loads with moderate starting or inrush currents.
Potential applications include:
Pumps
Fans
Motors
Control transformers
Solenoids
Contactors
Industrial automation equipment
Selected machinery
The actual tripping characteristic should be selected according to the load's starting current and protection-coordination requirements.
The Type AC characteristic is intended for compatible sinusoidal AC residual currents.
The 5SU1644-1RC32 should therefore be selected where the connected equipment is compatible with Type AC residual-current protection.
For modern power-electronic equipment, the leakage-current waveform should be checked before selecting Type AC instead of Type A, Type F or Type B protection.
The 5SU1644-1RC32 can be considered for compatible:
Industrial distribution boards
Three-phase equipment feeders
PCC panels
MCC panels
Machine power circuits
Commercial switchboards
Factory electrical systems
Sub-distribution boards
Building electrical panels
A typical circuit arrangement can be:
Incoming Supply → RCBO → Protected Three-Phase Load
Because the RCBO integrates overcurrent protection, the design should still consider:
Prospective short-circuit current
Cable capacity
Load current
C-curve characteristics
Residual-current sensitivity
Upstream protection
Applicable standards
RCBOs should be included in an appropriate electrical inspection and testing program.
The test function should be operated according to Siemens' instructions and applicable maintenance requirements to verify proper residual-current tripping.
Regular testing helps confirm that the protective mechanism remains operational.
Before selecting the 5SU1644-1RC32, verify:
Rated current: 32 A
Residual-current sensitivity: 300 mA
Residual-current type: Type AC
Tripping characteristic: C
Pole configuration: 4-pole
System voltage compatibility
Prospective short-circuit current
Required panel space: 8 modules
Cable size and installation method
Load inrush characteristics
Applicable electrical regulations
The 5SU1644-2RC32 is the corresponding 32 A, 4-pole, Type AC, 300 mA RCBO with a D characteristic. Siemens India product information confirms the D-curve variant with the same rated current, pole count, residual-current type and sensitivity.
Therefore:
5SU1644-1RC32 → C characteristic
5SU1644-2RC32 → D characteristic
The principal difference is the overcurrent tripping characteristic. The D curve is intended for compatible loads with higher starting or inrush currents.
The 5SU1644-1RC40 is the corresponding 40 A, 4-pole, Type AC, 300 mA, C-characteristic version.
Therefore:
5SU1644-1RC32 → 32 A
5SU1644-1RC40 → 40 A
The main difference is the rated current.
The 5SU1644-1RC63 is the corresponding 63 A, 4-pole, Type AC, 300 mA, C-characteristic version.
Therefore:
5SU1644-1RC32 → 32 A
5SU1644-1RC40 → 40 A
5SU1644-1RC63 → 63 A
The correct rated current should be selected according to the protected circuit.
The 5SU1644-7RC32 is a Type A variant in the same 5SU1 product family, while 5SU1644-1RC32 is specifically Type AC.
Therefore:
5SU1644-1RC32 → Type AC, C characteristic, 32 A, 300 mA
5SU1644-7RC32 → Type A, C characteristic, 32 A, 300 mA
The main difference is the residual-current type.
The 5SU1644-8RC32 is a Type A, D-characteristic, 32 A, 300 mA variant with a different modular configuration. Indian product data identifies it as a Type A 32 A, 300 mA D-curve RCBO.
Therefore, the exact article number should be checked for both residual-current type and tripping characteristic.
The 5SU1644-1RC32 is specifically a 300 mA RCBO.
Where a circuit design requires a 30 mA residual-current threshold, a different article must be selected. A lower sensitivity should not be substituted without confirming the protection requirements.
The 5SU1624 and 5SU1654 series contain other 2-pole RCBO configurations.
The 5SU1644-1RC32 is a 4-pole device intended for compatible three-phase-plus-neutral protection, so the pole configuration should be checked carefully when selecting an exact replacement.
The Siemens 5SU1644-1RC32 is relevant for:
Electrical panel builders
Industrial buyers
Electrical contractors
OEMs
Machine builders
Factory maintenance teams
Commercial electrical contractors
Electrical distributors
Automation system integrators
Electrical product dealers
For SB Smart, the product is positioned as a Siemens SENTRON / Betagard 5SU1 Type AC RCBO for 32 A three-phase circuit protection with C characteristic.
| Specification | Details |
|---|---|
| Brand | Siemens |
| Product Family | SENTRON / Betagard 5SU1 |
| Article Number | 5SU1644-1RC32 |
| Product Type | Residual Current Circuit Breaker with Overcurrent Protection (RCBO) |
| Rated Current | 32 A |
| Number of Poles | 4 Pole / 4P |
| Tripping Characteristic | C Curve |
| Residual Current Type | Type AC |
| Rated Residual Operating Current | 300 mA |
| Rated Voltage | 415 V AC market designation |
| Rated Frequency | 50 Hz |
| Short-Circuit Breaking Capacity | 10 kA |
| Module Width | 8 Modules |
| Installation | Modular electrical-panel / DIN-rail installation |
| Protection Functions | Overload + Short Circuit + Residual Current |
| Application | Three-phase + Neutral AC circuit protection |
The exact Indian product data confirms 32 A, 4-pole, 8 modules, C characteristic, Type AC, 300 mA and 10 kA for the article 5SU16441RC32.
Siemens SENTRON / Betagard 5SU1 RCBO
Article number 5SU1644-1RC32
32 A rated current
4-pole configuration
8-module installation designation
Type AC residual-current protection
300 mA residual-current sensitivity
C tripping characteristic
415 V AC India-market designation
50 Hz operating frequency
10 kA breaking capacity
Integrated overload protection
Integrated short-circuit protection
Integrated residual-current protection
Suitable for compatible three-phase-plus-neutral circuits
Suitable for industrial and commercial electrical panels
Combined protection: Integrates overload, short-circuit and residual-current protection in one device.
32 A rating: Suitable for compatible three-phase circuits and feeders.
Type AC protection: Designed for compatible sinusoidal AC residual currents.
300 mA sensitivity: Provides residual-current protection at the specified operating threshold.
C characteristic: Suitable for compatible loads with moderate inrush current.
4-pole design: Suitable for compatible three-phase-plus-neutral systems.
10 kA breaking capacity: Provides substantial short-circuit interruption capability within specified conditions.
8-module format: Provides a dedicated modular solution for the four-pole RCBO.
Siemens 5SU1 platform: Provides a standardized integrated circuit-protection solution.
The Siemens 5SU1644-1RC32 combines 32 A overcurrent protection, C-curve tripping and Type AC 300 mA residual-current protection in a four-pole RCBO.
The exact Indian product data confirms the combination of 32 A, 4-pole, 8 modules, C characteristic, Type AC and 300 mA, with a 10 kA breaking capacity.
It is suitable for customers looking to buy or source Siemens 5SU1 RCBOs for three-phase distribution boards, industrial feeders, machine circuits, electrical panels and commercial installations in India.
For SB Smart, this product is best presented as a Siemens Betagard/SENTRON 5SU1 Type AC RCBO for 32 A, 300 mA three-phase circuit protection with C characteristic across India.
SB Smart supplies Siemens SENTRON/Betagard RCBOs, RCCBs and industrial electrical protection products across Faridabad, Gurgaon/Gurugram, Delhi NCR, Haryana, Noida, Punjab, Mumbai and other major Indian cities.
Major delivery locations include:
Faridabad
Delhi
Gurgaon/Gurugram
Delhi NCR
Noida
Greater Noida
Haryana
Punjab
Mumbai
Pune
Ahmedabad
Bengaluru
Hyderabad
Chennai
Kolkata
Jaipur
Chandigarh
Lucknow
Indore
Surat
Vadodara
Nagpur
Coimbatore
And other major cities across India
The 5SU1644-1RC32 is a Siemens SENTRON / Betagard 5SU1 RCBO rated at 32 A, with 4 poles, C characteristic, Type AC residual-current protection and 300 mA sensitivity.
It is an RCBO, meaning it combines residual-current protection with overcurrent protection.
The rated current is 32 A.
The rated residual operating current is 300 mA.
It uses Type AC residual-current protection.
It has a C tripping characteristic.
It has 4 poles, suitable for compatible three-phase-plus-neutral applications.
8 modules refers to the product's market-facing modular installation designation. It indicates panel space and does not mean an 8 MW power rating.
Indian product information identifies the article for 415 V AC applications.
The exact product listing specifies a 10 kA breaking capacity.
5SU1644-1RC32: 32 A, 4-pole, Type AC, 300 mA, C characteristic.
5SU1644-2RC32: 32 A, 4-pole, Type AC, 300 mA, D characteristic.
The main difference is the overcurrent tripping characteristic.
SB Smart supplies Siemens SENTRON/Betagard 5SU1 RCBOs and industrial electrical protection products in India for panel builders, electrical contractors, OEMs, industrial buyers, machine builders and maintenance requirements.
|
Parameter |
Specification |
|
Product Series |
Siemens
Betagard 5SU1 |
|
Part Number |
5SU1644-1RC32 |
|
Product Type |
RCBO (Residual
Current Breaker with Overload Protection) |
|
Type |
Type AC |
|
Rated Current |
32 A |
|
Tripping Curve |
C
Characteristic |
|
Poles |
4 Pole (4P) |
|
Rated Voltage |
415 V AC |
|
Frequency |
50 Hz |
|
Residual
Current Protection |
Earth leakage
protection |
|
Mounting Type |
DIN Rail |
|
Degree of
Protection |
IP20 |
|
Standard |
IEC 61009-1 |
|
Application |
Commercial
& Industrial Distribution |
No reviews yet.