The Siemens 5SU1354-7RC40 is a SENTRON / Betagard 5SU1 Residual Current Circuit Breaker with Overcurrent Protection (RCBO) designed to combine overload, short-circuit and residual-current protection in one compact device. The exact Siemens datasheet specifies a 40 A rated current, 2-pole / 1P+N configuration, C tripping characteristic, Type A residual-current protection and 30 mA residual-current sensitivity. It is rated for 240 V AC, 50 Hz, with a 10 kA short-circuit breaking capacity according to EN 61009-1.
The 5SU1354-7RC40 belongs to the Siemens SENTRON / Betagard 5SU1 RCBO family. Unlike a conventional RCCB, an RCBO combines several protective functions in one device:
Overload protection
Short-circuit protection
Residual-current protection
This integrated arrangement can simplify circuit-level protection and reduce the need for separate MCB and RCCB devices.
The exact product description is RCBO 40 A, 2-pole, 2-module, C characteristic, Type A, 30 mA. Siemens' technical data confirms the same configuration.
The RCBO has a rated current of 40 A.
This makes it suitable for compatible single-phase circuits and feeders designed around a 40 A protective device.
The final selection should consider:
Connected load
Cable ampacity
Installation method
Ambient conditions
Prospective short-circuit current
Protection coordination requirements
Siemens' technical data confirms the 40 A rated current.
The 5SU1354-7RC40 uses a C tripping characteristic.
The C curve is intended for compatible circuits where normal operation may involve moderate starting or inrush current.
Potential applications include:
Pumps
Fans
Small motors
Control transformers
Contactors
Solenoids
Industrial auxiliary equipment
Selected electrical equipment
The actual C-curve selection should be based on load characteristics and protection coordination. Siemens specifies the article as C characteristic.
The RCBO uses Type A residual-current protection.
Type A devices are designed to detect compatible AC residual currents as well as pulsating DC residual-current components. This makes Type A protection suitable for many modern electrical and electronic loads.
Potential applications include:
Electronic power supplies
Rectifier circuits
Automation equipment
Industrial control equipment
Modern electrical machinery
Electronic equipment
The exact Siemens datasheet identifies the residual-current type as Type A.
The 5SU1354-7RC40 has a rated residual operating current of 30 mA.
When the residual-current condition reaches the specified operating threshold, the RCBO disconnects the protected circuit.
The 30 mA sensitivity should be selected according to the complete electrical protection design and applicable installation requirements.
Siemens specifies 30 mA as the rated tripping fault current.
The device has 2 poles, with a 1P+N configuration.
This makes it suitable for compatible single-phase circuits where phase and neutral are incorporated into the protection arrangement.
Typical applications include:
Single-phase distribution boards
Commercial electrical panels
Building electrical systems
Equipment feeders
Office circuits
Industrial auxiliary supplies
Control-panel circuits
Siemens specifies 2 poles and 1P+N configuration for the article.
The exact Siemens technical data specifies a 240 V AC supply voltage and 50 Hz operating frequency.
This makes the device suitable for compatible single-phase AC electrical systems within its specified ratings.
The 5SU1354-7RC40 has a 10 kA short-circuit current breaking capacity according to EN 61009-1.
The technical data additionally specifies 10 kA according to EN 60898, 15 kA according to IEC 60947-2, and 10 kA rated residual switching capacity according to IEC 61009-1.
The prospective short-circuit current at the installation point should still be checked during system design.
The main advantage of the 5SU1354-7RC40 is the integrated protection arrangement.
A conventional circuit may use:
MCB + RCCB
An RCBO combines these protective functions:
RCBO = Overload + Short Circuit + Residual Current Protection
This can simplify circuit-level protection and reduce panel component count.
The product is a 2-module RCBO.
Siemens specifies 2 modular width units, with a physical width of approximately 36 mm.
This compact design helps optimize space in:
DIN-rail distribution boards
Commercial panels
Control panels
Sub-distribution boards
Industrial electrical enclosures
The 2-module designation refers to physical panel width and does not indicate a power rating.
The 5SU1 RCBO family is designed for modular electrical-panel installation.
The 5SU1354-7RC40 can be integrated into suitable distribution boards and electrical panels alongside compatible protection and control devices.
Siemens specifies the mounting position as any, subject to the applicable installation instructions.
The overcurrent section of the RCBO protects the connected circuit against sustained excessive current resulting from overload.
The 40 A rating should be coordinated with:
Cable capacity
Load current
Installation method
Ambient temperature
Protection requirements
This helps protect the circuit while minimizing nuisance tripping.
The RCBO also provides integrated short-circuit protection.
With a specified 10 kA EN 61009-1 breaking capacity, the device is suitable for compatible installation conditions where the prospective fault current is within the specified limit.
Residual current occurs when part of the electrical current flows through an unintended path, such as leakage to earth.
The RCBO monitors the residual-current condition and disconnects the protected circuit when the specified 30 mA threshold is reached.
This adds residual-current protection to the integrated overload and short-circuit functions.
The Type A characteristic makes the 5SU1354-7RC40 suitable for compatible circuits where residual currents may include pulsating DC components.
Potential applications include:
Electronic equipment
Automation panels
Rectifier-based equipment
Control systems
Industrial machinery
Modern commercial electrical equipment
The actual residual-current waveform should be considered before selecting the protection device.
The C characteristic can be suitable for compatible loads with moderate starting or inrush current.
Potential applications include:
Pumps
Fans
Small motors
Solenoids
Control transformers
Contactors
Industrial auxiliary equipment
The exact application should be evaluated according to the load's starting characteristics.
The 5SU1354-7RC40 can be considered for compatible:
Commercial distribution boards
Building electrical panels
Equipment feeders
Office circuits
Control circuits
Industrial auxiliary circuits
Single-phase equipment supplies
The final application should follow the electrical design and applicable standards.
A typical arrangement can be:
Incoming Supply → RCBO → Protected Single-Phase Load
The complete protection design should consider:
Prospective short-circuit current
Cable capacity
Load current
C-curve characteristics
30 mA residual-current sensitivity
Upstream protection
Applicable electrical standards
The technical data specifies touch protection and neutral conductor switching for the device.
These features support the product's use in suitable modular distribution and circuit-protection applications.
Siemens specifies that the position of the power-supply connection can be either top or bottom.
This provides flexibility when arranging panel wiring and installation.
The device is specified as IP20 when installed in a suitable distribution board with connected conductors.
The RCBO should therefore be installed within an appropriate electrical enclosure or distribution assembly.
Siemens specifies an operating ambient temperature range of -25 °C to +55 °C for the product. Storage temperature is specified from -40 °C to +75 °C, subject to the manufacturer's conditions.
These ratings should be considered when installing the RCBO in electrical enclosures exposed to varying ambient conditions.
The 5SU1654-1RC40 is a Type AC RCBO with a different residual-current configuration, while the 5SU1354-7RC40 is specifically:
5SU1354-7RC40 → Type A, 40 A, 30 mA, C characteristic
The principal difference is the residual-current type and applicable protection characteristics.
The 5SU1 family also includes higher residual-current sensitivity variants.
The 5SU1354-7RC40 is specifically the 30 mA version.
A 300 mA RCBO should not be used as a direct replacement without confirming the required protection threshold.
The Siemens Type A C-characteristic range includes lower-current variants such as 32 A.
Therefore:
5SU1354-7RC32 → 32 A
5SU1354-7RC40 → 40 A
The primary difference is the rated current. Siemens' Type A C-characteristic range includes both 32 A and 40 A variants.
A 25 A variant is also available in the same Type A C-characteristic, 30 mA family.
Therefore:
5SU1354-7RC25 → 25 A
5SU1354-7RC40 → 40 A
The correct rated current should be selected according to the protected circuit.
The same family includes a 16 A Type A, C-characteristic, 30 mA variant.
Therefore:
5SU1354-7RC16 → 16 A
5SU1354-7RC40 → 40 A
The main difference is rated current.
The 5SU1444 family includes four-pole Type AC RCBOs, while 5SU1354-7RC40 is a 2-pole / 1P+N Type A device.
Therefore:
5SU1354-7RC40 → 2-pole / 1P+N, single-phase
5SU1444 variants → 4-pole, suitable three-phase-plus-neutral applications
The pole configuration must be matched to the electrical system.
The Siemens 5SU1354-7RC40 is relevant for:
Electrical panel builders
Industrial buyers
Electrical contractors
OEMs
Machine builders
Facility-maintenance teams
Commercial electrical contractors
Electrical distributors
Automation system integrators
Electrical product dealers
For SB Smart, the product is positioned as a Siemens Betagard/SENTRON 5SU1 Type A RCBO for 40 A, 30 mA single-phase circuit protection with C characteristic.
Siemens SENTRON / Betagard 5SU1 RCBO
Article number 5SU1354-7RC40
40 A rated current
2-pole / 1P+N configuration
2-module compact format
Type A residual-current protection
30 mA residual-current sensitivity
C tripping characteristic
240 V AC rated supply voltage
50 Hz operating frequency
10 kA EN 61009-1 breaking capacity
15 kA IEC 60947-2 switching capacity
10 kA residual switching capacity
Integrated overload protection
Integrated short-circuit protection
Integrated residual-current protection
Neutral conductor switching
Top or bottom power-supply connection
Touch protection
Suitable for compatible single-phase circuits
Combined protection: Provides overload, short-circuit and residual-current protection in one device.
40 A rating: Suitable for compatible higher-current single-phase circuits.
Type A protection: Suitable where residual currents may include pulsating DC components.
30 mA sensitivity: Provides residual-current protection at the specified operating threshold.
C characteristic: Suitable for compatible loads with moderate starting or inrush current.
2-module design: Helps optimize space in modular distribution boards.
10 kA breaking capacity: Provides substantial short-circuit interruption capability within specified conditions.
Neutral switching: Supports the 1P+N circuit arrangement.
Flexible supply connection: Power can be connected from the top or bottom.
The Siemens 5SU1354-7RC40 combines 40 A overcurrent protection, C-curve tripping and Type A 30 mA residual-current protection in a compact 2-pole, 2-module RCBO.
The exact Siemens technical data confirms 1P+N configuration, 40 A rated current, 30 mA residual-current sensitivity, Type A protection, C characteristic, 240 V AC operation and 10 kA EN 61009-1 short-circuit breaking capacity.
For SB Smart, this product is best presented as a Siemens Betagard/SENTRON 5SU1 Type A RCBO for 40 A, 30 mA single-phase circuit protection with C characteristic across India.
SB Smart supplies Siemens SENTRON/Betagard RCBOs, RCCBs and industrial electrical protection products across Faridabad, Gurgaon/Gurugram, Delhi NCR, Haryana, Noida, Punjab, Mumbai and other major Indian cities.
Major delivery locations include:
Faridabad
Delhi
Gurgaon/Gurugram
Delhi NCR
Noida
Greater Noida
Haryana
Punjab
Mumbai
Pune
Ahmedabad
Bengaluru
Hyderabad
Chennai
Kolkata
Jaipur
Chandigarh
Lucknow
Indore
Surat
Vadodara
Nagpur
Coimbatore
And other major cities across India
The 5SU1354-7RC40 is a Siemens SENTRON / Betagard 5SU1 RCBO rated at 40 A, with 2 poles / 1P+N, 2-module width, C characteristic, Type A residual-current protection and 30 mA sensitivity.
It is an RCBO, meaning it combines residual-current and overcurrent protection.
The rated current is 40 A.
The rated residual operating current is 30 mA.
It uses Type A residual-current protection.
It has a C tripping characteristic.
It has 2 poles in a 1P+N configuration.
It is a 2-module device with a physical width of approximately 36 mm.
The Siemens technical datasheet specifies 240 V AC rated supply voltage.
The specified short-circuit breaking capacity is 10 kA according to EN 61009-1. The datasheet also lists 15 kA according to IEC 60947-2.
5SU1354-7RC40: 40 A, Type A, 30 mA, C characteristic.
5SU1654-7RC40: 40 A, Type A, 300 mA, C characteristic.
The main difference is the residual-current sensitivity. The Siemens product range lists both 40 A variants with their respective residual-current ratings.
SB Smart supplies Siemens SENTRON/Betagard 5SU1 RCBOs and industrial electrical protection products in India for panel builders, electrical contractors, OEMs, industrial buyers, machine builders and maintenance requirements.
|
Parameter |
Specification |
|
Product Series |
Siemens
Betagard 5SU1 |
|
Part Number |
5SU1354-7RC40 |
|
Product Type |
RCBO (Residual
Current Breaker with Overload Protection) |
|
Type |
Type A |
|
Rated Current |
40 A |
|
Poles |
1P + N |
|
Tripping Curve |
C
Characteristic |
|
Residual
Current Sensitivity |
30 mA |
|
Rated Voltage |
230/400 V AC |
|
Breaking
Capacity |
10 kA |
|
Mounting Type |
DIN Rail |
|
Standard |
IEC 61009-1 |
|
Application |
Residential,
Commercial & Light Industrial Distribution |