The Siemens 5SU1354-1RC25 is a SENTRON / Betagard 5SU1 Residual Current Circuit Breaker with Overcurrent Protection (RCBO) designed to combine overload, short-circuit and residual-current protection in one compact device. The exact Siemens product is specified as a 25 A, 2-pole / 1P+N, 2-module, C-characteristic, Type AC, 30 mA RCBO with a 240 V AC supply voltage and 10 kA short-circuit breaking capacity according to EN 61009-1.
The 5SU1354-1RC25 belongs to the Siemens SENTRON / Betagard 5SU1 RCBO family. Unlike a conventional RCCB, an RCBO integrates multiple protection functions in one device:
Overload protection
Short-circuit protection
Residual-current protection
This integrated arrangement can simplify circuit-level protection and reduce the need for separate MCB and RCCB devices.
The exact product listing confirms the configuration as 25 A, 2-pole, 2-module, C characteristic, Type AC and 30 mA.
The 5SU1354-1RC25 has a rated current of 25 A.
This makes it suitable for compatible single-phase circuits designed around a 25 A protective device. The actual selection should consider cable ampacity, connected load, installation method, ambient temperature and applicable electrical regulations.
Siemens technical data specifies 25 A operational current at the AC rated value.
The RCBO uses a C tripping characteristic.
The C curve is intended for compatible circuits where normal operation can involve moderate starting or inrush current.
Potential applications include:
Pumps
Fans
Small motors
Contactors
Solenoids
Control transformers
Industrial auxiliary equipment
Selected electrical equipment
The C characteristic should be matched to the actual load and protection-coordination requirements. The exact Siemens data confirms the C characteristic.
The 5SU1354-1RC25 uses Type AC residual-current protection.
Type AC protection is intended for compatible sinusoidal alternating residual currents.
The residual-current waveform of the connected equipment should be considered before selecting Type AC. Equipment capable of producing pulsating DC or other residual-current components may require a different residual-current protection type.
The exact product data identifies the residual-current type as AC.
The 5SU1354-1RC25 has a rated residual operating current of 30 mA.
When the residual-current condition reaches the specified operating threshold, the RCBO disconnects the protected circuit.
The 30 mA sensitivity should be selected according to the overall electrical protection design and applicable installation requirements.
Siemens technical data confirms the 30 mA rated tripping fault current.
The device has 2 poles in a 1P+N configuration, with 1 protected pole.
This makes it suitable for compatible single-phase circuits where phase and neutral are incorporated into the switching/protection arrangement.
Typical applications include:
Single-phase distribution boards
Commercial electrical panels
Building electrical systems
Office circuits
Equipment feeders
Industrial auxiliary circuits
Control-panel supplies
The exact Siemens technical data specifies a 240 V AC supply voltage and 50 Hz operating frequency.
This makes the device suitable for compatible single-phase AC distribution systems within its specified electrical ratings.
The 5SU1354-1RC25 has a 10 kA short-circuit current breaking capacity according to EN 61009-1. Siemens data additionally specifies 10 kA according to EN 60898, 20 kA according to IEC 60947-2, and 10 kA rated residual switching capacity according to IEC 61009-1.
The prospective short-circuit current at the installation point should still be assessed during system design.
The exact technical data specifies energy limitation class 3.
This rating is relevant when evaluating the device's short-circuit energy-limiting characteristics within its applicable standard and installation conditions.
The 5SU1354-1RC25 is a 2-module RCBO.
Siemens specifies 2 modular width units and a physical width of 36 mm.
This compact arrangement is useful where panel space is limited, including:
DIN-rail distribution boards
Commercial panels
Control panels
Sub-distribution boards
Industrial electrical enclosures
The 2-module designation refers to physical panel space and does not represent a power rating.
The Siemens 5SU1 RCBO family is designed for modular electrical installation.
The 5SU1354-1RC25 can be integrated into compatible distribution boards and electrical panels alongside other DIN-mounted protection and control components.
The technical data specifies the mounting position as any, subject to the manufacturer's installation requirements.
The overcurrent section of the RCBO protects the connected circuit against sustained excessive current caused by overload.
The 25 A rated current should be coordinated with:
Cable ampacity
Connected load
Installation method
Ambient temperature
Protection requirements
Correct selection helps protect the circuit while minimizing nuisance tripping.
The RCBO also provides integrated short-circuit protection.
Its 10 kA EN 61009-1 breaking capacity should be considered against the prospective fault current at the installation point.
Residual current occurs when part of electrical current flows through an unintended path, such as leakage to earth.
The RCBO monitors this condition and disconnects the protected circuit when the residual-current operating threshold reaches 30 mA.
This adds residual-current protection to the integrated overload and short-circuit functions.
The C characteristic can be suitable for compatible loads with moderate inrush current.
Potential applications include:
Pumps
Fans
Small motors
Solenoids
Contactors
Control transformers
Industrial auxiliary equipment
Selected commercial equipment
The final selection should be evaluated according to the load's starting-current characteristics.
The 5SU1354-1RC25 is intended for compatible sinusoidal AC residual currents.
For modern electronic equipment containing rectifiers, variable-speed drives or other power electronics, the appropriate residual-current type should be verified before selecting Type AC.
The 5SU1354-1RC25 can be considered for compatible:
Commercial distribution boards
Building electrical panels
Office circuits
Equipment feeders
Industrial auxiliary circuits
Control-panel supplies
Single-phase equipment
Dedicated electrical circuits
The final application should follow the electrical design and applicable standards.
A typical arrangement can be:
Incoming Supply → RCBO → Protected Single-Phase Load
The complete protection design should consider:
Prospective short-circuit current
Cable capacity
Load current
C-curve characteristics
30 mA residual-current sensitivity
Upstream protection
Applicable electrical standards
The exact technical data specifies that the power-supply connection can be made from either the top or bottom.
This provides practical flexibility during panel wiring and installation.
The device is specified as IP20 when the distribution board is installed with connected conductors.
The RCBO should therefore be installed within a suitable electrical enclosure or distribution assembly.
The technical data specifies:
Operating temperature: -5 °C to +45 °C
Storage temperature: -40 °C to +75 °C
Maximum relative humidity: 95%
These conditions should be considered when selecting the installation location.
The supplied Siemens product designation states that the device is permitted in all countries and instructs users to observe national installation regulations.
For installations in India, applicable Indian electrical installation requirements and the manufacturer's instructions should be followed.
The 5SU1354-1RC16 is the corresponding 16 A, 2-pole, 2-module, C-characteristic, Type AC, 30 mA RCBO.
Therefore:
5SU1354-1RC16 → 16 A
5SU1354-1RC25 → 25 A
The main difference is the rated current. Siemens' current product range includes the 16 A Type AC, 30 mA, C-characteristic variant.
The 5SU1354-1RC32 is the corresponding 32 A, 2-pole, 2-module, C-characteristic, Type AC, 30 mA RCBO.
Therefore:
5SU1354-1RC25 → 25 A
5SU1354-1RC32 → 32 A
The primary difference is the rated current.
The 5SU1354-1RC40 is the corresponding 40 A, 2-pole, 2-module, C-characteristic, Type AC, 30 mA RCBO.
Therefore:
5SU1354-1RC25 → 25 A
5SU1354-1RC32 → 32 A
5SU1354-1RC40 → 40 A
The correct current rating should be matched to the protected circuit and cable design.
The 5SU1354-7RC25 belongs to the Type A version of this general 5SU1 RCBO configuration, whereas 5SU1354-1RC25 is specifically Type AC.
Therefore:
5SU1354-1RC25 → Type AC, 25 A, 30 mA
5SU1354-7RC25 → Type A, 25 A, 30 mA
The main difference is the residual-current type.
The 5SU1654-1RC25 is the corresponding 25 A, Type AC, C-characteristic, 300 mA configuration.
Therefore:
5SU1354-1RC25 → 25 A, 30 mA
5SU1654-1RC25 → 25 A, 300 mA
The main difference is residual-current sensitivity.
The 5SU1354-1RC25 is an RCBO, not simply an RCCB.
An RCCB primarily provides residual-current protection and normally requires separate overcurrent protection.
An RCBO combines:
Residual-current protection + overload protection + short-circuit protection
in a single device.
The Siemens 5SU1354-1RC25 is relevant for:
Electrical panel builders
Industrial buyers
Electrical contractors
OEMs
Machine builders
Facility-maintenance teams
Commercial electrical contractors
Electrical distributors
Automation system integrators
Electrical product dealers
For SB Smart, the product is positioned as a Siemens Betagard/SENTRON 5SU1 Type AC RCBO for 25 A, 30 mA single-phase circuit protection with C characteristic.
| Specification | Details |
|---|---|
| Brand | Siemens |
| Product Family | SENTRON / Betagard 5SU1 |
| Article Number | 5SU1354-1RC25 |
| Product Type | Residual Current Circuit Breaker with Overcurrent Protection (RCBO) |
| Rated Current | 25 A |
| Number of Poles | 2 Pole |
| Pole Configuration | 1P+N |
| Number of Protected Poles | 1 |
| Module Width | 2 Modules |
| Physical Width | 36 mm |
| Tripping Characteristic | C Curve |
| Residual Current Type | Type AC |
| Rated Residual Operating Current | 30 mA |
| Rated Operating Voltage | 240 V AC |
| Operating Frequency | 50 Hz |
| Insulation Voltage (Ui) | 264 V |
| Surge Voltage Resistance | 4 V as listed in supplied datasheet data |
| Short-Circuit Breaking Capacity | 10 kA according to EN 61009-1 |
| EN 60898 Switching Capacity | 10 kA |
| IEC 60947-2 Switching Capacity | 20 kA |
| Rated Residual Switching Capacity | 10 kA |
| Energy Limitation Class | 3 |
| Overvoltage Category | III |
| Pollution Degree | 2 |
| Protection Degree | IP20 when installed in a suitable distribution board |
| Power Supply Position | Top or bottom |
| Height | 90 mm |
| Width | 36 mm |
| Depth | 70 mm |
| Installation Depth | 70 mm |
| Mounting Position | Any |
| Ambient Operating Temperature | -5 °C to +45 °C |
| Storage Temperature | -40 °C to +75 °C |
| Maximum Relative Humidity | 95% |
These specifications are based on the Siemens technical data for 5SU1354-1RC25.
Siemens SENTRON / Betagard 5SU1 RCBO
Article number 5SU1354-1RC25
25 A rated current
2-pole / 1P+N configuration
2-module compact format
36 mm physical width
Type AC residual-current protection
30 mA residual-current sensitivity
C tripping characteristic
240 V AC rated supply voltage
50 Hz operating frequency
10 kA EN 61009-1 breaking capacity
20 kA IEC 60947-2 switching capacity
10 kA residual switching capacity
Energy limitation class 3
Top or bottom power-supply connection
Suitable for compatible single-phase circuits
Combined protection: Integrates overload, short-circuit and residual-current protection in one device.
25 A rating: Suitable for compatible single-phase circuits.
Type AC protection: Designed for compatible sinusoidal AC residual currents.
30 mA sensitivity: Provides residual-current protection at the specified operating threshold.
C characteristic: Suitable for compatible loads with moderate inrush current.
2-module design: Helps optimize space in modular distribution boards.
10 kA breaking capacity: Provides substantial short-circuit interruption capability within specified conditions.
1P+N configuration: Suitable for compatible phase-and-neutral single-phase circuits.
Flexible supply connection: Allows top or bottom power connection.
The Siemens 5SU1354-1RC25 combines 25 A overcurrent protection, C-curve tripping and Type AC 30 mA residual-current protection in a compact 2-pole, 2-module RCBO.
The exact technical data confirms 1P+N configuration, 25 A rated current, 30 mA residual-current sensitivity, Type AC protection, C characteristic, 240 V AC supply voltage and 10 kA EN 61009-1 short-circuit breaking capacity.
For SB Smart, this product is best presented as a Siemens Betagard/SENTRON 5SU1 Type AC RCBO for 25 A, 30 mA single-phase circuit protection with C characteristic across India.
SB Smart supplies Siemens SENTRON/Betagard RCBOs, RCCBs and industrial electrical protection products across Faridabad, Gurgaon/Gurugram, Delhi NCR, Haryana, Noida, Punjab, Mumbai and other major Indian cities.
Major delivery locations include:
Faridabad
Delhi
Gurgaon/Gurugram
Delhi NCR
Noida
Greater Noida
Haryana
Punjab
Mumbai
Pune
Ahmedabad
Bengaluru
Hyderabad
Chennai
Kolkata
Jaipur
Chandigarh
Lucknow
Indore
Surat
Vadodara
Nagpur
Coimbatore
And other major cities across India
The 5SU1354-1RC25 is a Siemens SENTRON / Betagard 5SU1 RCBO rated at 25 A, with 2 poles / 1P+N, 2-module width, C characteristic, Type AC residual-current protection and 30 mA sensitivity.
It is an RCBO, combining residual-current and overcurrent protection in one device.
The rated current is 25 A.
The rated residual operating current is 30 mA.
It uses Type AC residual-current protection.
It has a C tripping characteristic.
It has 2 poles in a 1P+N configuration.
It is a 2-module RCBO with a physical width of 36 mm.
The exact product data specifies 240 V AC at 50 Hz.
The product is specified at 10 kA according to EN 61009-1, with 20 kA according to IEC 60947-2 for the applicable switching-capacity specification.
5SU1354-1RC25: 25 A, Type AC, 30 mA, C characteristic.
5SU1354-1RC32: 32 A, Type AC, 30 mA, C characteristic.
The main difference is the rated current.
5SU1354-1RC25: Type AC, 25 A, 30 mA, C characteristic.
5SU1354-7RC25: Type A, 25 A, 30 mA, C characteristic.
The main difference is the residual-current type.
SB Smart supplies Siemens SENTRON/Betagard 5SU1 RCBOs and industrial electrical protection products in India for panel builders, electrical contractors, OEMs, industrial buyers, machine builders and maintenance requirements.
|
Parameter |
Specification |
|
Product
Series |
Siemens
Betagard 5SU1 |
|
Part Number |
5SU1354-1RC25 |
|
Product Type |
RCBO
(Residual Current Breaker with Overcurrent Protection) |
|
Residual
Current Type |
Type A |
|
Rated
Current |
25 A |
|
Tripping
Characteristic |
C Curve |
|
Rated
Residual Current |
30 mA |
|
Poles |
1P+N (2
Pole) |
|
Rated
Voltage |
230–240 V AC |
|
Frequency |
50/60 Hz |
|
Breaking
Capacity |
10 kA |
|
Mounting
Type |
DIN Rail |
|
Protection |
Overload,
Short Circuit & Earth Leakage |
|
Standard |
IEC 61009-1
/ IEC 60947-2 |
|
Application |
Residential,
Commercial & Light Industrial |
No reviews yet.