RCBO 10 A 2-pole 2-module C characteristic type AC 30 mA, permitted in all countries. Observe national installation regulations! 5SU1354-1RC10

(0 Reviews)
Best Price (Excl. GST):
9,775 / nos MRP: ₹9,775 / nos
GST (18%): 1,760
Total Price (Incl. GST): ₹11,535
Available as per OEM Lead Time
Quantity:
nos
Secure
Fast Delivery
24/7 Support

100% Genuine Product

Industrial Grade

Quality Tested

GST Invoice Available

Product Description

Siemens 5SU1354-1RC10 RCBO – 10A, 2-Pole, 30mA, Type AC, C-Characteristic

The Siemens 5SU1354-1RC10 is a SENTRON / Betagard 5SU1 Residual Current Circuit Breaker with Overcurrent Protection (RCBO) designed to provide combined overload, short-circuit and residual-current protection in one compact device. The exact product specification identifies it as a 10 A, 2-pole / 1P+N, 2-module, C-characteristic, Type AC, 30 mA RCBO for compatible single-phase electrical circuits.

The product is intended for applications requiring both circuit overcurrent protection and residual-current protection in a compact modular device. The supplied Siemens designation also states that the product is permitted in all countries, subject to applicable national installation regulations.

Siemens 5SU1354-1RC10 RCBO

The 5SU1354-1RC10 belongs to the Siemens SENTRON / Betagard 5SU1 RCBO family.

Unlike a conventional RCCB, an RCBO combines:

  • Overload protection

  • Short-circuit protection

  • Residual-current protection

in a single device.

This integrated construction can simplify electrical-panel design and provide dedicated protection to individual circuits without requiring separate MCB and RCCB devices.

10 A Rated Current

The RCBO has a rated current of 10 A.

This makes it suitable for compatible single-phase circuits designed around a 10 A protective device.

Typical circuit applications can include:

  • Lighting circuits

  • Control circuits

  • Instrumentation circuits

  • Small electronic equipment

  • Building auxiliary circuits

  • Automation control circuits

  • Small single-phase equipment

The final current rating should always be selected according to the connected load, conductor capacity, installation method and applicable regulations.

C Tripping Characteristic

The 5SU1354-1RC10 uses a C tripping characteristic.

The C curve is intended for compatible circuits where normal operation may involve moderate starting or inrush current.

Potential applications include:

  • Small motors

  • Fans

  • Pumps

  • Contactors

  • Solenoids

  • Control transformers

  • Selected lighting equipment

  • Industrial auxiliary loads

The C characteristic should be matched to the actual load and protection-coordination requirements.

Type AC Residual Current Protection

The device uses Type AC residual-current protection.

Type AC protection is designed for compatible sinusoidal alternating residual currents.

Before selecting Type AC, the residual-current waveform of the connected equipment should be considered. Equipment that can produce pulsating DC or other residual-current components may require a different residual-current protection type.

30 mA Residual Current Sensitivity

The 5SU1354-1RC10 has a rated residual operating current of 30 mA.

When the residual-current condition reaches the specified operating threshold, the RCBO disconnects the protected circuit.

The 30 mA sensitivity should be selected according to the complete electrical protection design and applicable installation requirements.

This model should not automatically be substituted with a 100 mA or 300 mA device because those have different residual-current operating thresholds.

2-Pole / 1P+N Configuration

The device has 2 poles in a 1P+N configuration.

This arrangement is suitable for compatible single-phase circuits where phase and neutral are incorporated into the switching and protection arrangement.

Typical applications include:

  • Single-phase distribution boards

  • Commercial electrical panels

  • Office circuits

  • Building electrical systems

  • Equipment feeders

  • Industrial auxiliary circuits

  • Control-panel supplies

240 V AC Application

The 5SU1354-1RC10 is intended for compatible single-phase AC applications in the 240 V AC class.

The actual installation voltage should always be checked against the exact Siemens technical documentation and the electrical-system design.

Short-Circuit Protection

The RCBO incorporates short-circuit protection as part of its overcurrent function.

The short-circuit capability should be checked against the prospective fault current at the installation point and the applicable Siemens product rating.

This allows the RCBO to provide both circuit overcurrent and residual-current protection in a single compact unit.

Combined Overcurrent and Residual-Current Protection

A conventional circuit arrangement may require:

MCB + RCCB

The RCBO combines the relevant functions:

RCBO = Overload + Short Circuit + Residual Current Protection

This can reduce component count and simplify circuit-level protection in electrical distribution boards.

Compact 2-Module Design

The 5SU1354-1RC10 is specified as a 2-module device.

A 2-module modular format occupies approximately 36 mm of standard panel width.

This compact construction is useful for:

  • DIN-rail distribution boards

  • Commercial electrical panels

  • Control panels

  • Sub-distribution boards

  • Industrial electrical enclosures

The 2-module designation refers to physical panel space and does not represent a power rating.

DIN-Rail / Modular Installation

The Siemens 5SU1 RCBO family is designed for modular electrical installation.

The 5SU1354-1RC10 can be integrated into suitable DIN-rail distribution boards and electrical panels alongside compatible protective and control components.

Installation should follow Siemens' product instructions, wiring requirements and applicable national regulations.

Overload Protection

The overcurrent section of the RCBO protects the connected circuit against sustained excessive current caused by overload.

The 10 A rating should be coordinated with:

  • Cable ampacity

  • Connected load

  • Installation method

  • Ambient conditions

  • Protection requirements

Correct coordination helps protect the circuit while minimizing nuisance tripping.

Short-Circuit Protection

The RCBO's overcurrent section also provides protection against short-circuit conditions.

The prospective short-circuit current at the installation point should be checked against the product's specified breaking capacity and the complete protection arrangement.

Residual-Current Protection

Residual current occurs when part of the electrical current flows outside its intended path, such as through an unintended leakage path to earth.

The RCBO monitors the relevant condition and disconnects the protected circuit when the residual-current threshold reaches 30 mA.

This provides residual-current protection in addition to overload and short-circuit protection.

C-Curve Applications

The C characteristic can be useful for compatible loads that experience moderate inrush current.

Potential applications include:

  • Small pumps

  • Fans

  • Small motors

  • Solenoids

  • Contactors

  • Control transformers

  • Industrial auxiliary equipment

  • Selected commercial loads

The actual selection should be based on the load's starting characteristics and protection coordination.

Type AC Load Compatibility

The 5SU1354-1RC10 is intended for compatible sinusoidal AC residual currents.

For modern electronic equipment with rectifiers, variable-speed drives or other power-electronic circuits, the required residual-current type should be verified before choosing Type AC.

Single-Phase Electrical Applications

The 5SU1354-1RC10 can be considered for compatible:

  • Lighting circuits

  • Control circuits

  • Instrumentation circuits

  • Commercial distribution boards

  • Office electrical systems

  • Building auxiliary circuits

  • Automation panels

  • Small equipment feeders

The final application should follow the electrical-system design and applicable standards.

Protection Coordination

A typical circuit arrangement can be:

Incoming Supply → RCBO → Protected Single-Phase Load

The overall protection design should consider:

  • Prospective short-circuit current

  • Cable capacity

  • Load current

  • C-curve characteristics

  • 30 mA residual-current sensitivity

  • Upstream protection

  • Applicable national installation regulations

Power-Supply Connection

The Siemens 5SU1 design allows flexible panel wiring according to the relevant product configuration and installation instructions.

The exact wiring arrangement should always be checked against the manufacturer's terminal and connection diagram before installation.

IP20 Protection

The RCBO should be installed inside a suitable distribution board or electrical enclosure to provide the required environmental and touch protection.

The protection degree depends on the completed installation and enclosure arrangement.

Environmental Conditions

The device should be installed within the manufacturer's specified ambient conditions.

Electrical-panel designers should consider:

  • Ambient temperature

  • Humidity

  • Ventilation

  • Enclosure conditions

  • Installation altitude

  • Applicable derating requirements

These factors can affect protective-device performance.

Permitted Countries and National Installation Regulations

The supplied Siemens product description states that the 5SU1354-1RC10 is permitted in all countries and specifically instructs users to observe national installation regulations.

For installations in India, the applicable Indian electrical installation requirements and Siemens installation instructions should be followed.

Difference from 16 A Version

The 5SU1354-1RC16 is the corresponding 16 A, 2-pole, 2-module, C-characteristic, Type AC, 30 mA RCBO.

Therefore:

5SU1354-1RC10 → 10 A

5SU1354-1RC16 → 16 A

The main difference is the rated current.

Difference from 20 A Version

The 5SU1354-1RC20 is the corresponding 20 A, 2-pole, 2-module, C-characteristic, Type AC, 30 mA RCBO.

Therefore:

5SU1354-1RC10 → 10 A

5SU1354-1RC20 → 20 A

The main difference is the rated current.

Difference from 25 A Version

The 5SU1354-1RC25 is the corresponding 25 A, 2-pole, 2-module, C-characteristic, Type AC, 30 mA RCBO.

Therefore:

5SU1354-1RC10 → 10 A

5SU1354-1RC25 → 25 A

The correct rated current should be selected according to the protected circuit and conductor capacity.

Difference from 32 A Version

The 5SU1354-1RC32 is the corresponding 32 A, 2-pole, 2-module, C-characteristic, Type AC, 30 mA RCBO.

Therefore:

5SU1354-1RC10 → 10 A

5SU1354-1RC32 → 32 A

The main difference is rated current.

Difference from 40 A Version

The 5SU1354-1RC40 is the corresponding 40 A, 2-pole, 2-module, C-characteristic, Type AC, 30 mA RCBO.

Therefore:

5SU1354-1RC10 → 10 A

5SU1354-1RC40 → 40 A

The main difference is rated current.

Difference from Type A Version

The 5SU1354-7RC10 belongs to the Type A version of the Siemens 5SU1 RCBO family, while 5SU1354-1RC10 is specifically Type AC.

Therefore:

5SU1354-1RC10 → Type AC, 10 A, 30 mA, C

5SU1354-7RC10 → Type A, 10 A, 30 mA, C

The key difference is the residual-current type.

Difference from 300 mA Type AC Version

The 5SU1654-1RC10 belongs to the Type AC, 300 mA configuration.

Therefore:

5SU1354-1RC10 → 10 A, Type AC, 30 mA

5SU1654-1RC10 → 10 A, Type AC, 300 mA

The main difference is the residual-current sensitivity.

Difference Between RCBO and RCCB

The 5SU1354-1RC10 is an RCBO.

An RCCB primarily provides residual-current protection and normally requires separate overcurrent protection.

An RCBO combines:

Residual-current protection + overload protection + short-circuit protection

in one device.

Suitable for Electrical Panel Builders and Industrial Buyers

The Siemens 5SU1354-1RC10 is relevant for:

  • Electrical panel builders

  • Industrial buyers

  • Electrical contractors

  • OEMs

  • Machine builders

  • Facility-maintenance teams

  • Commercial electrical contractors

  • Electrical distributors

  • Automation system integrators

  • Electrical product dealers

For SB Smart, the product is positioned as a Siemens Betagard/SENTRON 5SU1 Type AC RCBO for 10 A, 30 mA single-phase circuit protection with C characteristic.

Technical Specification

SpecificationDetails
BrandSiemens
Product FamilySENTRON / Betagard 5SU1
Article Number5SU1354-1RC10
Product TypeResidual Current Circuit Breaker with Overcurrent Protection (RCBO)
Rated Current10 A
Number of Poles2 Pole
Pole Configuration1P+N
Protected Poles1
Module Width2 Modules
Physical Width36 mm
Tripping CharacteristicC Curve
Residual Current TypeType AC
Rated Residual Operating Current30 mA
Rated Operating Voltage240 V AC
Operating Frequency50 Hz
Insulation Voltage264 V
Short-Circuit Breaking Capacity10 kA class
Residual Switching Capacity10 kA class
Energy Limitation Class3
Overvoltage CategoryIII
Pollution Degree2
InstallationModular / DIN-rail
ApplicationSingle-phase AC circuit protection
National Regulation RequirementObserve applicable national installation regulations

The product designation supplied for this article confirms the 10 A, 2-pole, 2-module, C characteristic, Type AC, 30 mA configuration.

Key Features

  • Siemens SENTRON / Betagard 5SU1 RCBO

  • Article number 5SU1354-1RC10

  • 10 A rated current

  • 2-pole / 1P+N

  • 2-module compact format

  • 36 mm physical width

  • Type AC residual-current protection

  • 30 mA residual-current sensitivity

  • C tripping characteristic

  • 240 V AC supply category

  • 50 Hz operating frequency

  • Integrated overload protection

  • Integrated short-circuit protection

  • Integrated residual-current protection

  • Suitable for compatible single-phase circuits

  • Permitted in all countries subject to national installation regulations

Benefits

  • Combined protection: Integrates overload, short-circuit and residual-current protection in one device.

  • 10 A rating: Suitable for compatible low-current single-phase circuits.

  • Type AC protection: Designed for compatible sinusoidal AC residual currents.

  • 30 mA sensitivity: Provides residual-current protection at the specified operating threshold.

  • C characteristic: Suitable for compatible loads with moderate inrush current.

  • 2-module design: Helps optimize panel space.

  • 1P+N configuration: Suitable for compatible phase-and-neutral circuits.

  • Integrated protection: Reduces the need for separate MCB and RCCB components.

  • Siemens 5SU1 platform: Provides a compact circuit-protection solution.

Why Choose Siemens 5SU1354-1RC10?

The Siemens 5SU1354-1RC10 combines 10 A overcurrent protection, C-curve tripping and Type AC 30 mA residual-current protection in a compact 2-pole, 2-module RCBO.

It is suitable for customers looking for an integrated protection device for compatible single-phase circuits in commercial, building and industrial electrical systems.

For SB Smart, this product is best presented as a Siemens Betagard/SENTRON 5SU1 Type AC RCBO for 10 A, 30 mA single-phase circuit protection with C characteristic across India.

Delivery Across India

SB Smart supplies Siemens SENTRON/Betagard RCBOs, RCCBs and industrial electrical protection products across Faridabad, Gurgaon/Gurugram, Delhi NCR, Haryana, Noida, Punjab, Mumbai and other major Indian cities.

Major delivery locations include:

  • Faridabad

  • Delhi

  • Gurgaon/Gurugram

  • Delhi NCR

  • Noida

  • Greater Noida

  • Haryana

  • Punjab

  • Mumbai

  • Pune

  • Ahmedabad

  • Bengaluru

  • Hyderabad

  • Chennai

  • Kolkata

  • Jaipur

  • Chandigarh

  • Lucknow

  • Indore

  • Surat

  • Vadodara

  • Nagpur

  • Coimbatore

  • And other major cities across India

Frequently Asked Questions

1. What is Siemens 5SU1354-1RC10?

The 5SU1354-1RC10 is a Siemens SENTRON / Betagard 5SU1 RCBO rated at 10 A, with 2 poles / 1P+N, 2-module width, C characteristic, Type AC residual-current protection and 30 mA sensitivity.

2. Is this an RCBO or RCCB?

It is an RCBO, combining residual-current and overcurrent protection in one device.

3. What is the rated current?

The rated current is 10 A.

4. What is the residual-current sensitivity?

The rated residual operating current is 30 mA.

5. What type of residual-current protection does it use?

It uses Type AC residual-current protection.

6. What is the tripping characteristic?

It has a C tripping characteristic.

7. How many poles does it have?

It has 2 poles in a 1P+N configuration.

8. What is the module width?

It is a 2-module RCBO with approximately 36 mm physical width.

9. What is the rated voltage?

The product is specified for the 240 V AC supply category.

10. What is the difference between 5SU1354-1RC10 and 5SU1354-1RC16?

5SU1354-1RC10: 10 A, Type AC, 30 mA, C characteristic.

5SU1354-1RC16: 16 A, Type AC, 30 mA, C characteristic.

The main difference is the rated current.

11. What is the difference between 5SU1354-1RC10 and 5SU1354-7RC10?

5SU1354-1RC10: Type AC, 10 A, 30 mA, C characteristic.

5SU1354-7RC10: Type A, 10 A, 30 mA, C characteristic.

The key difference is the residual-current type.

12. What is the difference between 5SU1354-1RC10 and 5SU1654-1RC10?

5SU1354-1RC10: 10 A, Type AC, 30 mA, C characteristic.

5SU1654-1RC10: 10 A, Type AC, 300 mA, C characteristic.

The main difference is residual-current sensitivity.

13. Where can I buy Siemens 5SU1354-1RC10 in India?

SB Smart supplies Siemens SENTRON/Betagard 5SU1 RCBOs and industrial electrical protection products in India for panel builders, electrical contractors, OEMs, industrial buyers, machine builders and maintenance requirements.

Technical Specifications

ParameterSpecification
Product SeriesSiemens SENTRON
Part Number5SU1354-1RC10
Product TypeRCBO (Residual Current Circuit Breaker with Overcurrent Protection)
Number of Poles1P+N (2 Pole)
Rated Current (In)10A
Residual Current Sensitivity (IΔn)30mA
Residual Current TypeType AC
Tripping CharacteristicC Curve
Rated Voltage240V AC
Frequency50Hz
Breaking Capacity (Icn)10kA
Breaking Capacity (IEC 60947-2)20kA
Protection FunctionsOverload, Short Circuit & Earth Leakage Protection
Mounting TypeDIN Rail Mounting
Width2 Module
Degree of ProtectionIP20
Terminal TypeScrew Terminal
Standard ComplianceIEC / EN 61009
ApplicationDistribution Boards, Residential Installations, Commercial Buildings, Industrial Control Panels

Customer Reviews

Write a Review

No reviews yet.

Why Buy From SB Smart?

Authorized Supplier
Genuine products directly from manufacturers with warranty support.
Industrial Expertise
Over 10 years of experience in industrial automation and electricals.
PAN India Delivery
Fast and secure shipping to all major industrial hubs across India.
Dedicated Support
Expert technical team available for product selection and support.

Request a Quote

×
Product: Product Name

Thank You!

Your quote request has been submitted successfully.

Our team will contact you shortly.

Product Enquiry

×
Enquiring for: Product Name

Enquiry Sent!

We have received your enquiry.

Our team will get back to you soon.