The Siemens 5SU1354-1RC06 is a SENTRON / Betagard 5SU1 Residual Current Circuit Breaker with Overcurrent Protection (RCBO) designed to combine overload, short-circuit and residual-current protection in one compact device. The exact Siemens data specifies a 6 A rated current, 2-pole / 1P+N configuration, 2-module width, C tripping characteristic, Type AC residual-current protection and 30 mA residual operating current. It is specified for 240 V AC, 50 Hz, with a 10 kA short-circuit current breaking capacity according to EN 61009-1.
The 5SU1354-1RC06 belongs to the Siemens SENTRON / Betagard 5SU1 RCBO family. Unlike a conventional RCCB, an RCBO integrates several protection functions into one device:
Overload protection
Short-circuit protection
Residual-current protection
This integrated design can simplify circuit-level protection and reduce the need for separate MCB and RCCB devices.
Siemens documentation lists 5SU1354-1RC06 within the 5SU1 RCBO range, and the exact technical datasheet confirms the Type AC, C-curve, 30 mA configuration.
The 5SU1354-1RC06 has a rated current of 6 A.
This makes it suitable for compatible low-current single-phase circuits designed around a 6 A protective device.
Potential applications include:
Lighting circuits
Control circuits
Instrumentation circuits
Automation circuits
Small electronic equipment
Building auxiliary circuits
Small single-phase loads
The exact Siemens data confirms an operational current of 6 A at the AC rated value.
The RCBO uses a C tripping characteristic.
The C curve is intended for compatible circuits where normal operation can involve moderate starting or inrush current.
Potential applications include:
Small motors
Fans
Pumps
Contactors
Solenoids
Control transformers
Selected lighting systems
Industrial auxiliary circuits
The exact product datasheet confirms C characteristic.
The 5SU1354-1RC06 uses Type AC residual-current protection.
Type AC protection is intended for compatible sinusoidal alternating residual currents.
The leakage-current waveform of the connected equipment should be considered before selecting Type AC. Equipment capable of producing pulsating DC or other residual-current components may require another residual-current protection type.
The exact Siemens technical data identifies the residual-current type as AC.
The RCBO has a rated residual operating current of 30 mA.
When the residual-current condition reaches the specified operating threshold, the device disconnects the protected circuit.
The exact Siemens datasheet confirms 30 mA rated tripping fault current.
The device has 2 poles with a 1P+N configuration, including one protected pole.
This makes it suitable for compatible single-phase circuits where phase and neutral are incorporated into the switching/protection arrangement.
Typical applications include:
Single-phase distribution boards
Commercial electrical panels
Office circuits
Building electrical systems
Control-panel supplies
Equipment feeders
Industrial auxiliary circuits
The exact technical data specifies a 240 V AC supply voltage and 50 Hz operating frequency.
This makes the article suitable for compatible single-phase AC distribution systems within its specified ratings.
The 5SU1354-1RC06 has a 10 kA short-circuit current breaking capacity according to EN 61009-1.
The technical data also specifies:
10 kA according to EN 60898
35 kA according to IEC 60947-2
10 kA rated residual switching capacity according to IEC 61009-1
Energy limitation class 3
The prospective short-circuit current at the installation point should still be checked during system design.
The exact technical data specifies energy limitation class 3.
This characteristic is relevant when evaluating the device's short-circuit energy-limiting behaviour within its applicable standards and installation conditions.
The 5SU1354-1RC06 is specified as a 2-module RCBO.
Siemens gives a physical width of 36 mm and 2 modular width units.
This compact format is useful for:
DIN-rail distribution boards
Commercial panels
Control panels
Sub-distribution boards
Industrial electrical enclosures
The 2-module designation refers to physical panel space and does not indicate a power rating.
The Siemens 5SU1 RCBO family is designed for modular electrical installation.
The 5SU1354-1RC06 can be integrated into compatible distribution boards and electrical panels alongside other DIN-mounted protection and control devices.
The exact mounting arrangement should follow Siemens' installation instructions and applicable national electrical regulations.
The overcurrent section of the RCBO protects the connected circuit against sustained excessive current caused by overload.
The 6 A rating should be coordinated with:
Cable ampacity
Connected load
Installation method
Ambient conditions
Protection requirements
Correct coordination helps protect the circuit while minimizing nuisance tripping.
The RCBO also provides integrated short-circuit protection.
Its 10 kA EN 61009-1 breaking capacity should be considered against the prospective fault current at the installation point.
Residual current occurs when part of the electrical current flows through an unintended path, such as leakage to earth.
The RCBO monitors this condition and disconnects the protected circuit when the residual-current operating threshold reaches 30 mA.
This adds residual-current protection to the integrated overload and short-circuit functions.
The C characteristic can be suitable for compatible loads with moderate inrush current.
Potential applications include:
Small pumps
Fans
Small motors
Solenoids
Contactors
Control transformers
Industrial auxiliary equipment
Selected commercial equipment
The actual application should be evaluated according to the load's starting-current characteristics.
The 5SU1354-1RC06 is intended for compatible sinusoidal AC residual currents.
For modern electronic equipment containing rectifiers, variable-speed drives or other power electronics, the appropriate residual-current type should be verified before selecting Type AC.
The 5SU1354-1RC06 can be considered for compatible:
Lighting circuits
Control circuits
Instrumentation circuits
Commercial distribution boards
Building auxiliary circuits
Automation panels
Small equipment feeders
Single-phase electrical circuits
The final application should follow the electrical design and applicable standards.
A typical arrangement can be:
Incoming Supply → RCBO → Protected Single-Phase Load
The complete protection design should consider:
Prospective short-circuit current
Cable capacity
Load current
C-curve characteristics
30 mA residual-current sensitivity
Upstream protection
Applicable national installation regulations
The exact Siemens data specifies that the power-supply connection can be positioned either at the top or bottom.
This provides practical flexibility during electrical-panel wiring.
The exact product data specifies IP20 when the distribution board is installed with connected conductors.
The RCBO should therefore be installed inside a suitable electrical enclosure or distribution assembly.
Siemens specifies:
Operating ambient temperature: -5 °C to +45 °C
Storage temperature: -40 °C to +75 °C
Maximum relative humidity: 95%
These conditions should be considered when selecting the installation location and enclosure.
The supplied product designation states that the 5SU1354-1RC06 is permitted in all countries and instructs users to observe national installation regulations. The same wording appears in the exact product datasheet.
For installations in India, applicable Indian electrical installation requirements and Siemens installation instructions should be followed.
The 5SU1354-7RC06 is a Type A variant listed in the Siemens 5SU1 range, while 5SU1354-1RC06 is specifically Type AC. Siemens documentation lists both article numbers.
Therefore:
5SU1354-1RC06 → Type AC, 6 A, 30 mA, C
5SU1354-7RC06 → Type A, 6 A, 30 mA, C
The key difference is the residual-current type.
The 5SU1354-1RC10 is the corresponding 10 A, 2-pole, 2-module, C-characteristic, Type AC, 30 mA version.
Therefore:
5SU1354-1RC06 → 6 A
5SU1354-1RC10 → 10 A
The principal difference is rated current. Siemens documentation lists both exact article numbers.
The 5SU1354-1RC16 is the corresponding 16 A version with the same general Type AC, C-characteristic and 30 mA configuration.
Therefore:
5SU1354-1RC06 → 6 A
5SU1354-1RC16 → 16 A
The main difference is rated current.
The 5SU1354-1RC20 is the corresponding 20 A variant.
Therefore:
5SU1354-1RC06 → 6 A
5SU1354-1RC20 → 20 A
The main difference is rated current.
The 5SU1354-1RC25 is the corresponding 25 A, Type AC, C-characteristic, 30 mA RCBO.
Therefore:
5SU1354-1RC06 → 6 A
5SU1354-1RC25 → 25 A
The correct current rating should be matched to the protected circuit and conductor capacity.
The 5SU1354-1RC32 is the corresponding 32 A variant.
Therefore:
5SU1354-1RC06 → 6 A
5SU1354-1RC32 → 32 A
The main difference is rated current.
The 5SU1354-1RC40 is the corresponding 40 A variant.
Therefore:
5SU1354-1RC06 → 6 A
5SU1354-1RC40 → 40 A
The main difference is rated current.
The 5SU1654-1RC06 belongs to the 6 A, Type AC, C-characteristic, 300 mA configuration.
Therefore:
5SU1354-1RC06 → 6 A, Type AC, 30 mA
5SU1654-1RC06 → 6 A, Type AC, 300 mA
The key difference is the residual-current operating threshold.
The 5SU1354-1RC06 is an RCBO, not simply an RCCB.
An RCCB primarily provides residual-current protection and normally requires separate overcurrent protection.
An RCBO combines:
Residual-current protection + overload protection + short-circuit protection
in one device.
The Siemens 5SU1354-1RC06 is relevant for:
Electrical panel builders
Industrial buyers
Electrical contractors
OEMs
Machine builders
Facility-maintenance teams
Commercial electrical contractors
Electrical distributors
Automation system integrators
Electrical product dealers
For SB Smart, the product is positioned as a Siemens Betagard/SENTRON 5SU1 Type AC RCBO for 6 A, 30 mA single-phase circuit protection with C characteristic.
| Specification | Details |
|---|---|
| Brand | Siemens |
| Product Family | SENTRON / Betagard 5SU1 |
| Article Number | 5SU1354-1RC06 |
| Product Type | Residual Current Circuit Breaker with Overcurrent Protection (RCBO) |
| Rated Current | 6 A |
| Number of Poles | 2 Pole |
| Pole Configuration | 1P+N |
| Number of Protected Poles | 1 |
| Module Width | 2 Modules |
| Physical Width | 36 mm |
| Tripping Characteristic | C Curve |
| Residual Current Type | Type AC |
| Rated Residual Operating Current | 30 mA |
| Rated Supply Voltage | 240 V AC |
| Operating Frequency | 50 Hz |
| Insulation Voltage (Ui) | 264 V |
| Surge Voltage Resistance | 4 V as listed in the product data |
| Short-Circuit Breaking Capacity | 10 kA according to EN 61009-1 |
| EN 60898 Switching Capacity | 10 kA |
| IEC 60947-2 Switching Capacity | 35 kA |
| Rated Residual Switching Capacity | 10 kA |
| Energy Limitation Class | 3 |
| Overvoltage Category | III |
| Pollution Degree | 2 |
| Protection Degree | IP20 when installed in a suitable distribution board |
| Power Supply Position | Top or bottom |
| Height | 90 mm |
| Width | 36 mm |
| Depth | 70 mm |
| Installation Depth | 70 mm |
| Mounting Position | Any |
| Ambient Operating Temperature | -5 °C to +45 °C |
| Storage Temperature | -40 °C to +75 °C |
| Maximum Relative Humidity | 95% |
These specifications are based on the exact Siemens technical data sheet for 5SU1354-1RC06.
Siemens SENTRON / Betagard 5SU1 RCBO
Article number 5SU1354-1RC06
6 A rated current
2-pole / 1P+N configuration
2-module compact format
36 mm physical width
Type AC residual-current protection
30 mA residual-current sensitivity
C tripping characteristic
240 V AC rated supply voltage
50 Hz operating frequency
10 kA EN 61009-1 short-circuit breaking capacity
35 kA IEC 60947-2 switching capacity
10 kA residual switching capacity
Energy limitation class 3
Top or bottom power-supply connection
Suitable for compatible single-phase electrical circuits
Combined protection: Integrates overload, short-circuit and residual-current protection in one device.
6 A rating: Suitable for compatible low-current single-phase circuits.
Type AC protection: Designed for compatible sinusoidal AC residual currents.
30 mA sensitivity: Provides residual-current protection at the specified operating threshold.
C characteristic: Suitable for compatible loads with moderate inrush current.
2-module design: Helps optimize space in modular distribution boards.
1P+N configuration: Suitable for compatible phase-and-neutral circuits.
10 kA breaking capacity: Provides substantial short-circuit interruption capability within specified conditions.
Siemens 5SU1 platform: Provides a compact integrated circuit-protection solution.
The Siemens 5SU1354-1RC06 combines 6 A overcurrent protection, C-curve tripping and Type AC 30 mA residual-current protection in a compact 2-pole, 2-module RCBO.
The exact Siemens data confirms 1P+N configuration, 6 A rated current, 30 mA residual-current sensitivity, Type AC protection, C characteristic, 240 V AC supply voltage and 10 kA EN 61009-1 short-circuit breaking capacity.
For SB Smart, this product is best presented as a Siemens Betagard/SENTRON 5SU1 Type AC RCBO for 6 A, 30 mA single-phase circuit protection with C characteristic across India.
SB Smart supplies Siemens SENTRON/Betagard RCBOs, RCCBs and industrial electrical protection products across Faridabad, Gurgaon/Gurugram, Delhi NCR, Haryana, Noida, Punjab, Mumbai and other major Indian cities.
Major delivery locations include:
Faridabad
Delhi
Gurgaon/Gurugram
Delhi NCR
Noida
Greater Noida
Haryana
Punjab
Mumbai
Pune
Ahmedabad
Bengaluru
Hyderabad
Chennai
Kolkata
Jaipur
Chandigarh
Lucknow
Indore
Surat
Vadodara
Nagpur
Coimbatore
And other major cities across India
The 5SU1354-1RC06 is a Siemens SENTRON / Betagard 5SU1 RCBO rated at 6 A, with 2 poles / 1P+N, 2-module width, C characteristic, Type AC residual-current protection and 30 mA sensitivity.
It is an RCBO, combining residual-current and overcurrent protection in one device.
The rated current is 6 A.
The rated residual operating current is 30 mA.
It uses Type AC residual-current protection.
It has a C tripping characteristic.
It has 2 poles in a 1P+N configuration.
It is a 2-module RCBO with a physical width of 36 mm.
The exact technical data specifies 240 V AC at 50 Hz.
The product is specified at 10 kA according to EN 61009-1, with 35 kA according to IEC 60947-2 for the applicable switching-capacity parameter.
5SU1354-1RC06: 6 A, Type AC, 30 mA, C characteristic.
5SU1354-7RC06: 6 A, Type A, 30 mA, C characteristic.
The key difference is the residual-current type.
5SU1354-1RC06: 6 A, Type AC, 30 mA, C characteristic.
5SU1654-1RC06: 6 A, Type AC, 300 mA, C characteristic.
The main difference is the residual-current sensitivity.
SB Smart supplies Siemens SENTRON/Betagard 5SU1 RCBOs and industrial electrical protection products in India for panel builders, electrical contractors, OEMs, industrial buyers, machine builders and maintenance requirements.
|
Parameter |
Specification |
|
Product Series |
Siemens Betagard 5SU1 |
|
Part Number |
5SU1354-1RC06 |
|
Product Type |
RCBO (Residual Current Breaker with Overcurrent
Protection) |
|
Residual Current Type |
Type A |
|
Rated Current |
6 A |
|
Tripping Characteristic |
C Curve |
|
Rated Residual Current |
30 mA (typical series value) |
|
Poles |
2 Pole (1P+N) |
|
Rated Voltage |
230–240 V AC |
|
Frequency |
50/60 Hz |
|
Breaking Capacity |
10 kA |
|
Mounting Type |
DIN Rail |
|
Protection |
Overload, Short Circuit & Earth Leakage |
|
Standard |
IEC 61009-1 / IEC 60947-2 |
|
Application |
Residential, Commercial & Light Industrial |