The Siemens 5SU1344-7RC63 is a SENTRON / Betagard 5SU1 Residual Current Circuit Breaker with Overcurrent Protection (RCBO) designed to combine overload, short-circuit and residual-current protection in one device. The exact Siemens datasheet specifies a 63 A rated current, 4-pole configuration, 7 modular-width units, C tripping characteristic, Type A residual-current protection and 30 mA residual-current sensitivity. It is rated for 415 V AC, 50 Hz and has a 10 kA short-circuit breaking capacity according to EN 61009-1.
The 5SU1344-7RC63 belongs to the Siemens SENTRON / Betagard 5SU1 RCBO family. An RCBO combines overcurrent protection and residual-current protection in one integrated device.
It provides protection against:
Overload
Short circuit
Residual or earth-leakage current
This integrated arrangement can simplify circuit-level protection compared with using separate MCB and RCCB devices.
The exact product description confirms 63 A, 4-pole, 7 modules, C characteristic, Type A and 30 mA.
The RCBO has a rated current of 63 A.
This makes it suitable for compatible higher-current three-phase circuits and feeders designed around a 63 A protective device.
The final selection should consider cable capacity, connected load, installation method, ambient temperature, prospective fault current and applicable electrical regulations.
The 5SU1344-7RC63 uses a C tripping characteristic.
The C curve is suitable for compatible circuits where normal operation may involve moderate starting or inrush currents.
Potential applications include:
Motors
Pumps
Fans
Control transformers
Contactors
Solenoids
Industrial auxiliary equipment
Selected machinery
The actual tripping characteristic should be selected according to the load's starting-current characteristics and protection coordination.
The device uses Type A residual-current protection.
Type A protection is designed to detect suitable AC residual currents as well as pulsating DC residual-current components. This makes Type A suitable for many modern electrical and electronic loads.
Potential applications include:
Electronic power supplies
Automation equipment
Rectifier-based equipment
Industrial control systems
Modern machinery
Commercial electronic equipment
The exact Siemens datasheet identifies the residual-current type as A.
The 5SU1344-7RC63 has a rated residual operating current of 30 mA.
When the residual-current condition reaches the applicable operating threshold, the RCBO disconnects the protected circuit.
The 30 mA sensitivity should be selected according to the electrical protection design and applicable installation requirements. The exact Siemens data confirms 30 mA residual-current sensitivity.
The RCBO has 4 poles, making it suitable for compatible three-phase-plus-neutral electrical systems.
The four-pole arrangement allows the three phases and neutral to be incorporated into the protection arrangement.
Typical applications include:
Three-phase distribution boards
Industrial feeder circuits
PCC panels
MCC panels
Commercial electrical panels
Machine power circuits
Factory electrical systems
Sub-distribution boards
The exact product data specifies 4 poles / 4P, with all four poles protected.
The exact Siemens technical data specifies a 415 V AC supply voltage and 50 Hz operating frequency.
This makes the product suitable for compatible three-phase low-voltage distribution systems where the voltage and protection requirements match the device.
The 5SU1344-7RC63 has a 10 kA short-circuit breaking capacity according to EN 61009-1.
The technical data also specifies:
10 kA according to EN 60898
15 kA according to IEC 60947-2
10 kA rated residual switching capacity according to IEC 61009-1
Energy limitation class 3
The prospective short-circuit current at the installation point should still be checked during system design.
The principal advantage of the 5SU1344-7RC63 is its integrated protection architecture.
A conventional arrangement may use:
MCB + RCCB
An RCBO combines these functions:
RCBO = Overload + Short Circuit + Residual Current Protection
This can simplify circuit-level protection and reduce the number of separate protective devices.
The exact Siemens product specifies 7 modular width units.
The technical datasheet gives a physical width of 126 mm, corresponding to the stated 7-module configuration.
The 7-module designation refers to physical panel space and does not represent a power rating.
The Siemens technical data specifies approximately:
Height: 90 mm
Width: 126 mm
Depth: 70 mm
Installation depth: 70 mm
Modular width: 7 units
Mounting position: Any
These dimensions are useful for electrical panel builders when checking enclosure and DIN-rail space.
The technical data specifies neutral conductor switching.
This supports the four-pole protection arrangement used in compatible three-phase-plus-neutral systems.
Siemens specifies that the power-supply connection can be positioned either at the top or bottom.
This provides flexibility during electrical-panel wiring.
The overcurrent section protects the connected circuit against sustained excessive current caused by overload.
The 63 A rating should be coordinated with:
Cable ampacity
Connected load
Installation method
Ambient temperature
Protection-coordination requirements
The RCBO also provides integrated short-circuit protection.
The specified 10 kA EN 61009-1 breaking capacity should be considered against the prospective fault current at the installation point.
Residual current occurs when part of the electrical current flows through an unintended path, such as leakage toward earth.
The RCBO monitors this condition and disconnects the protected circuit when the specified 30 mA residual-current threshold is reached.
This adds residual-current protection to the integrated overload and short-circuit functions.
The C characteristic can be suitable for compatible loads with moderate starting or inrush current.
Potential applications include:
Pumps
Fans
Motors
Solenoids
Contactors
Control transformers
Industrial machinery
Automation equipment
The actual application should be evaluated according to load starting characteristics and protection coordination.
Type A protection is suitable for compatible applications where residual currents can include pulsating DC components.
Potential applications include:
Automation systems
Electronic control panels
Switching power supplies
Rectifier-based equipment
Industrial instrumentation
Modern electrical machinery
The connected equipment's leakage-current waveform should be checked before final selection.
The 5SU1344-7RC63 can be considered for compatible:
Industrial distribution boards
Three-phase equipment feeders
PCC panels
MCC panels
Machine power circuits
Commercial switchboards
Factory electrical systems
Sub-distribution boards
Building electrical panels
A typical arrangement can be:
Incoming Supply → RCBO → Protected Three-Phase Load
The complete protection design should consider:
Prospective short-circuit current
Cable capacity
Load current
C-curve characteristics
30 mA residual-current sensitivity
Upstream protection
Applicable electrical standards
RCBOs should be included in an appropriate electrical inspection and testing program.
The test function should be operated according to Siemens' instructions and applicable maintenance requirements to verify the residual-current protection function.
Regular testing helps confirm that the protective mechanism remains operational.
Before selecting the 5SU1344-7RC63, verify:
Rated current: 63 A
Residual-current sensitivity: 30 mA
Residual-current type: Type A
Tripping characteristic: C
Pole configuration: 4-pole
Rated voltage: 415 V AC
Operating frequency: 50 Hz
Short-circuit capacity: 10 kA
Required panel space: 7 modules
Cable size and installation method
Load starting characteristics
Applicable national regulations
The 5SU1344-8RC63 is the corresponding 63 A, 4-pole, 7-module, Type A, 30 mA RCBO with a D characteristic.
Therefore:
5SU1344-7RC63 → C characteristic
5SU1344-8RC63 → D characteristic
The main difference is the overcurrent tripping characteristic. The D curve is intended for compatible loads with higher starting or inrush currents.
The 5SU1644-1RC63 is a Type AC, C-characteristic RCBO with a 300 mA residual-current rating.
The 5SU1344-7RC63 is specifically:
63 A + 4-pole + 7 modules + C characteristic + Type A + 30 mA
Therefore, both residual-current type and sensitivity must be checked before choosing an alternative.
The 5SU1644-7RC63 is a 63 A, 4-pole, 7-module, C-characteristic, Type A, 300 mA RCBO.
Therefore:
5SU1344-7RC63 → Type A, 30 mA
5SU1644-7RC63 → Type A, 300 mA
The main difference is residual-current sensitivity.
The 5SU1444-7RC63 is the corresponding 63 A, 4-pole, 7-module, C-characteristic, Type A, 100 mA configuration.
Therefore:
5SU1344-7RC63 → Type A, 30 mA
5SU1444-7RC63 → Type A, 100 mA
5SU1644-7RC63 → Type A, 300 mA
This comparison is useful when selecting the exact residual-current sensitivity.
The 5SU1324 family includes 2-pole Type A RCBO variants, while the 5SU1344-7RC63 is a 4-pole device for compatible three-phase-plus-neutral applications.
The pole configuration should therefore be checked carefully before selecting a replacement.
The 5SU1344-7RC63 is an RCBO.
An RCCB primarily provides residual-current protection and generally needs separate overcurrent protection.
An RCBO combines:
Residual-current protection + overload protection + short-circuit protection
in one device.
The Siemens 5SU1344-7RC63 is relevant for:
Electrical panel builders
Industrial buyers
Electrical contractors
OEMs
Machine builders
Factory maintenance teams
Commercial electrical contractors
Electrical distributors
Automation system integrators
Electrical product dealers
For SB Smart, the product is positioned as a Siemens SENTRON / Betagard 5SU1 Type A RCBO for 63 A three-phase circuit protection with C characteristic and 30 mA sensitivity.
| Specification | Details |
|---|---|
| Brand | Siemens |
| Product Family | SENTRON / Betagard 5SU1 |
| Article Number | 5SU1344-7RC63 |
| Product Type | Residual Current Circuit Breaker with Overcurrent Protection (RCBO) |
| Rated Current | 63 A |
| Number of Poles | 4 Pole / 4P |
| Number of Protected Poles | 4 |
| Tripping Characteristic | C Curve |
| Residual Current Type | Type A |
| Rated Residual Operating Current | 30 mA |
| Rated Operating Voltage | 415 V AC |
| Operating Frequency | 50 Hz |
| Insulation Voltage (Ui) | 440 V |
| Surge Voltage Resistance | 4 kV |
| Short-Circuit Breaking Capacity | 10 kA according to EN 61009-1 |
| EN 60898 Switching Capacity | 10 kA |
| IEC 60947-2 Switching Capacity | 15 kA |
| Rated Residual Switching Capacity | 10 kA |
| Energy Limitation Class | 3 |
| Overvoltage Category | III |
| Pollution Degree | 2 |
| Protection Degree | IP20 when installed in a suitable distribution board |
| Neutral Conductor Switching | Yes |
| Touch Protection | Yes |
| Power Supply Position | Top or bottom |
| Height | 90 mm |
| Width | 126 mm |
| Depth | 70 mm |
| Installation Depth | 70 mm |
| Modular Width Units | 7 |
| Mounting Position | Any |
| Operating Ambient Temperature | -25 °C to +45 °C |
These specifications are taken from the exact Siemens technical data for 5SU1344-7RC63.
Siemens SENTRON / Betagard 5SU1 RCBO
Article number 5SU1344-7RC63
63 A rated current
4-pole configuration
7-module format
Type A residual-current protection
30 mA residual-current sensitivity
C tripping characteristic
415 V AC rated voltage
50 Hz operating frequency
10 kA EN 61009-1 breaking capacity
15 kA IEC 60947-2 switching capacity
10 kA rated residual switching capacity
440 V insulation voltage
4 kV surge-voltage resistance
Neutral conductor switching
Top or bottom power-supply connection
Integrated overload and short-circuit protection
Integrated residual-current protection
Suitable for compatible three-phase-plus-neutral circuits
Combined protection: Integrates overload, short-circuit and residual-current protection in one device.
63 A rating: Suitable for compatible higher-current three-phase circuits.
Type A protection: Suitable where residual currents may include pulsating DC components.
30 mA sensitivity: Provides residual-current protection at the specified operating threshold.
C characteristic: Suitable for compatible loads with moderate inrush current.
4-pole design: Suitable for compatible three-phase-plus-neutral systems.
7-module format: Provides a modular four-pole protection solution.
10 kA breaking capacity: Provides substantial short-circuit interruption capability within specified conditions.
Neutral switching: Supports the four-pole circuit arrangement.
Flexible supply connection: Power can be connected from the top or bottom.
The Siemens 5SU1344-7RC63 combines 63 A overcurrent protection, C-curve tripping and Type A 30 mA residual-current protection in a 4-pole, 7-module RCBO.
The exact Siemens data confirms 415 V AC, 50 Hz, 63 A, 4-pole configuration, Type A, 30 mA sensitivity, C characteristic and 10 kA EN 61009-1 short-circuit breaking capacity.
For SB Smart, this product is best presented as a Siemens Betagard/SENTRON 5SU1 Type A RCBO for 63 A, 30 mA three-phase circuit protection with C characteristic across India.
SB Smart supplies Siemens SENTRON/Betagard RCBOs, RCCBs and industrial electrical protection products across Faridabad, Gurgaon/Gurugram, Delhi NCR, Haryana, Noida, Punjab, Mumbai and other major Indian cities.
Major delivery locations include:
Faridabad
Delhi
Gurgaon/Gurugram
Delhi NCR
Noida
Greater Noida
Haryana
Punjab
Mumbai
Pune
Ahmedabad
Bengaluru
Hyderabad
Chennai
Kolkata
Jaipur
Chandigarh
Lucknow
Indore
Surat
Vadodara
Nagpur
Coimbatore
And other major cities across India
The 5SU1344-7RC63 is a Siemens SENTRON / Betagard 5SU1 RCBO rated at 63 A, with 4 poles, 7 modules, C characteristic, Type A residual-current protection and 30 mA sensitivity.
It is an RCBO, meaning it combines residual-current and overcurrent protection.
The rated current is 63 A.
The rated residual operating current is 30 mA.
It uses Type A residual-current protection.
It has a C tripping characteristic.
It has 4 poles, suitable for compatible three-phase-plus-neutral applications.
The exact Siemens data specifies 7 modular width units and a physical width of 126 mm.
The exact Siemens technical data specifies 415 V AC at 50 Hz.
The specified breaking capacity is 10 kA according to EN 61009-1, with 15 kA according to IEC 60947-2 for the applicable switching-capacity parameter.
5SU1344-7RC63: 63 A, 4-pole, Type A, 30 mA, C characteristic.
5SU1344-8RC63: 63 A, 4-pole, Type A, 30 mA, D characteristic.
The main difference is the overcurrent tripping characteristic.
5SU1344-7RC63: Type A, 30 mA.
5SU1444-7RC63: Type A, 100 mA.
5SU1344-7RC63: Type A, 30 mA.
5SU1644-7RC63: Type A, 300 mA.
SB Smart supplies Siemens SENTRON/Betagard 5SU1 RCBOs and industrial electrical protection products in India for panel builders, electrical contractors, OEMs, industrial buyers, machine builders and maintenance requirements.
|
Parameter |
Specification |
|
Product Series |
Siemens Betagard 5SU1 |
|
Part Number |
5SU1344-7RC63 |
|
Product Type |
RCBO (Residual Current Breaker with Overcurrent
Protection) |
|
Residual Current Type |
Type AC |
|
Rated Current |
63 A |
|
Tripping Characteristic |
C Curve |
|
Rated Residual Current |
30 mA |
|
Poles |
4 Pole |
|
Rated Voltage |
400–415 V AC |
|
Frequency |
50/60 Hz |
|
Breaking Capacity |
10 kA |
|
Mounting Type |
DIN Rail |
|
Protection |
Overload, Short Circuit & Earth Leakage |
|
Standard |
IEC 61009-1 / IEC 60947-2 |
|
Application |
Residential, Commercial & Light Industrial |
No reviews yet.