info@sbsyscon.in +91 98995 98955

SB Smart

Industrial & Electrical Solutions

Welcome Back

Login to access your account

Don't have an account? Register Now
Siemens Logo

RCBO 32 A 4-pole 8 modules C characteristic type AC 30 mA, use of these devices is not permitted in all countries. Observe national installation regulations! - 5SU1344 -1RC32

(0 Reviews)
Best Price (Excl. GST):
14,820 / nos MRP: ₹14,820 / nos
GST (18%): 2,668
Total Price (Incl. GST): ₹17,488
Available as per OEM Lead Time
Quantity:
nos
Secure
Fast Delivery
24/7 Support

100% Genuine Product

Industrial Grade

Quality Tested

GST Invoice Available

Product Description

Siemens 5SU1344-1RC32 RCBO – 32A, 4-Pole, 30mA, Type AC, C-Characteristic

The Siemens 5SU1344-1RC32 is a SENTRON / Betagard 5SU1 Residual Current Circuit Breaker with Overcurrent Protection (RCBO) designed to combine overload, short-circuit and residual-current protection in a single device. The exact Siemens product designation specifies 32 A, 4-pole, 8 modules, C characteristic, Type AC and 30 mA residual-current sensitivity. The technical datasheet specifies 415 V AC, 50 Hz, 10 kA short-circuit breaking capacity according to EN 61009-1, and 15 kA according to IEC 60947-2. Siemens also states that use of these devices is not permitted in all countries, so national installation regulations must be observed.

Siemens 5SU1344-1RC32 RCBO

The 5SU1344-1RC32 belongs to the Siemens SENTRON / Betagard 5SU1 RCBO family.

An RCBO integrates:

  • Overload protection

  • Short-circuit protection

  • Residual-current protection

in one device.

This integrated construction can simplify circuit-level protection compared with separate MCB and RCCB arrangements. Siemens documentation includes 5SU1344-1RC32 within the 5SU1 four-pole RCBO family.

32 A Rated Current

The RCBO has a rated current of 32 A.

It is suitable for compatible three-phase circuits and feeders designed around a 32 A protective device.

The final selection should consider:

  • Connected load

  • Cable ampacity

  • Installation method

  • Ambient conditions

  • Prospective short-circuit current

  • Protection coordination

  • Applicable electrical regulations

The exact product datasheet confirms 32 A operational current at AC rated value.

C Tripping Characteristic

The 5SU1344-1RC32 uses a C tripping characteristic.

The C curve is suitable for compatible circuits where moderate starting or inrush current can occur during normal operation.

Potential applications include:

  • Pumps

  • Fans

  • Motors

  • Control transformers

  • Contactors

  • Solenoids

  • Industrial auxiliary equipment

  • Selected machinery

The exact Siemens technical data confirms the C tripping characteristic.

Type AC Residual Current Protection

The device uses Type AC residual-current protection.

Type AC protection is intended for compatible sinusoidal alternating residual currents.

The leakage-current waveform of connected equipment should be evaluated before selecting Type AC. Equipment capable of producing pulsating DC or other residual-current components may require a different residual-current type.

The exact Siemens article is specified as Type AC.

30 mA Residual Current Sensitivity

The 5SU1344-1RC32 has a rated residual operating current of 30 mA.

When the residual-current condition reaches the applicable operating threshold, the RCBO disconnects the protected circuit.

The 30 mA sensitivity should be selected according to the complete electrical protection design and applicable installation regulations. The exact datasheet confirms 30 mA tripping fault current.

4-Pole Configuration

The RCBO has 4 poles, making it suitable for compatible three-phase-plus-neutral electrical systems.

The four-pole arrangement incorporates the three phases and neutral into the circuit protection arrangement.

Typical applications include:

  • Three-phase distribution boards

  • Industrial feeder circuits

  • PCC panels

  • MCC panels

  • Commercial electrical panels

  • Machine power circuits

  • Factory electrical systems

  • Sub-distribution boards

The exact technical data specifies 4 poles and 4 protected poles.

415 V AC Application

The exact Siemens technical data specifies 415 V AC rated supply voltage and 50 Hz operating frequency.

This makes the device suitable for compatible three-phase low-voltage electrical systems where the system voltage and protection requirements match the RCBO.

10 kA Short-Circuit Breaking Capacity

The 5SU1344-1RC32 has a 10 kA short-circuit breaking capacity according to EN 61009-1.

The same technical data specifies:

  • 10 kA according to EN 60898

  • 15 kA according to IEC 60947-2

  • 10 kA rated residual switching capacity according to IEC 61009-1

  • Energy limitation class 3

The prospective short-circuit current at the installation point should still be verified during system design.

Combined Overcurrent and Residual-Current Protection

The main advantage of the 5SU1344-1RC32 is its integrated protection arrangement.

A conventional circuit may use:

MCB + RCCB

An RCBO combines these functions:

RCBO = Overload + Short Circuit + Residual Current Protection

This can simplify panel construction and provide dedicated circuit-level protection.

8-Module Product Designation

The supplied Siemens product designation identifies this article as an 8-module RCBO.

The technical data, however, lists a physical width of 126 mm and 7 modular width units.

For the SB Smart product page, the supplied market-facing description “8 modules” can be retained in the product title, while the technical table can separately mention 7 modular width units / 126 mm physical width.

The module designation refers to physical panel space and does not represent a power rating.

Physical Dimensions

The technical data specifies approximately:

  • Height: 90 mm

  • Width: 126 mm

  • Depth: 70 mm

  • Installation depth: 70 mm

  • Modular width units: 7

  • Mounting position: Any

These dimensions are useful for panel builders when planning DIN-rail and enclosure space.

DIN-Rail / Modular Installation

The Siemens 5SU1 RCBO family is designed for modular electrical installations.

The 5SU1344-1RC32 can be integrated into suitable:

  • Distribution boards

  • Industrial control panels

  • PCC panels

  • MCC panels

  • Commercial switchboards

  • Machine panels

  • Factory electrical enclosures

Installation should follow Siemens' current mounting and wiring instructions.

Neutral Conductor Switching

The technical data confirms neutral conductor switching.

This supports the four-pole arrangement used in compatible three-phase-plus-neutral applications.

Flexible Power-Supply Connection

The technical data specifies that the power supply can be connected from either the top or bottom.

This provides practical flexibility during panel wiring.

Overload Protection

The overcurrent section protects the connected circuit against sustained excessive current caused by overload.

The 32 A rating should be coordinated with:

  • Cable ampacity

  • Connected load

  • Installation method

  • Ambient temperature

  • Protection-coordination requirements

Short-Circuit Protection

The RCBO also provides integrated short-circuit protection.

Its 10 kA EN 61009-1 breaking capacity should be evaluated against the prospective fault current at the installation point.

Residual-Current Protection

Residual current occurs when part of the electrical current flows through an unintended path, such as leakage toward earth.

The RCBO monitors this condition and disconnects the protected circuit when the specified 30 mA residual-current threshold is reached.

This adds residual-current protection to the integrated overload and short-circuit functions.

C-Curve Industrial Applications

The C characteristic can be suitable for compatible loads with moderate starting or inrush current.

Potential applications include:

  • Pumps

  • Fans

  • Motors

  • Solenoids

  • Contactors

  • Control transformers

  • Industrial machinery

  • Automation equipment

The actual application should be evaluated according to the load's starting characteristics and protection coordination.

Type AC Applications

The 5SU1344-1RC32 is intended for compatible circuits with suitable sinusoidal AC residual currents.

For modern equipment containing rectifiers, variable-speed drives or other power electronics, the required residual-current type should be checked before selecting Type AC.

Three-Phase Distribution Applications

The 5SU1344-1RC32 can be considered for compatible:

  • Industrial distribution boards

  • Three-phase equipment feeders

  • PCC panels

  • MCC panels

  • Machine power circuits

  • Commercial switchboards

  • Factory electrical systems

  • Sub-distribution boards

  • Building electrical panels

Protection Coordination

A typical arrangement can be:

Incoming Supply → RCBO → Protected Three-Phase Load

The complete protection design should consider:

  • Prospective short-circuit current

  • Cable capacity

  • Load current

  • C-curve characteristics

  • 30 mA residual-current sensitivity

  • Upstream protection

  • Applicable electrical standards

Maintenance and Testing

RCBOs should be included in an appropriate electrical inspection and testing program.

The test function should be operated according to Siemens' instructions and applicable maintenance requirements to verify residual-current protection.

Regular testing helps confirm that the protection mechanism remains operational.

Installation Considerations

Before selecting the 5SU1344-1RC32, verify:

  • Rated current: 32 A

  • Residual-current sensitivity: 30 mA

  • Residual-current type: Type AC

  • Tripping characteristic: C

  • Pole configuration: 4-pole

  • Rated voltage: 415 V AC

  • Operating frequency: 50 Hz

  • Short-circuit breaking capacity: 10 kA according to EN 61009-1

  • Panel space requirements

  • Cable size and installation method

  • Load starting characteristics

  • Applicable national installation regulations

Important Country-Specific Installation Note

The exact Siemens product description explicitly states:

“Use of these devices is not permitted in all countries. Observe national installation regulations!”

This warning should remain visible on the SB Smart product page because the permitted use of this particular RCBO depends on the electrical installation rules applicable in the country of installation.

For India, the installer should verify the applicable Indian requirements and current Siemens documentation before installation.

Difference from Type A Version

The 5SU1344-7RC32 is the corresponding 32 A, 4-pole, 7-module, C-characteristic, Type A, 30 mA configuration.

Therefore:

5SU1344-1RC32 → Type AC, 32 A, 30 mA

5SU1344-7RC32 → Type A, 32 A, 30 mA

The main difference is the residual-current type, with the product designation also differing in modular configuration. Siemens documentation lists both articles in the 5SU1 range.

Difference from D-Characteristic Version

The 5SU1344-2RC32 is the corresponding 32 A, 4-pole, Type AC, 30 mA RCBO with a D characteristic. Siemens documentation lists the article in the same 5SU1 family.

Therefore:

5SU1344-1RC32 → C characteristic

5SU1344-2RC32 → D characteristic

The principal difference is the overcurrent tripping characteristic.

Difference from 100 mA Type AC Version

A Type AC, C-characteristic 32 A RCBO with 100 mA sensitivity belongs to a different 5SU1 configuration.

Therefore:

5SU1344-1RC32 → 32 A, Type AC, 30 mA

The residual-current sensitivity should always be checked before selecting an alternative.

Difference from 300 mA Type AC Version

The 5SU1644-1RC32 is the corresponding 32 A, 4-pole, Type AC, C-characteristic, 300 mA configuration. Siemens documentation lists both 5SU1344-1RC32 and 5SU1644-1RC32 in the 5SU1 product family.

Therefore:

5SU1344-1RC32 → 32 A, Type AC, 30 mA

5SU1644-1RC32 → 32 A, Type AC, 300 mA

The main difference is residual-current sensitivity.

Difference from 40 A Version

The 5SU1344-1RC40 is the corresponding 40 A, 4-pole, Type AC, C-characteristic, 30 mA configuration. Siemens documentation lists both articles in the same family.

Therefore:

5SU1344-1RC32 → 32 A

5SU1344-1RC40 → 40 A

The main difference is rated current.

Difference from 63 A Version

The 5SU1344-1RC63 is the corresponding higher-rated configuration.

Therefore:

5SU1344-1RC32 → 32 A

5SU1344-1RC40 → 40 A

5SU1344-1RC63 → 63 A

The correct current rating should be selected according to the protected circuit and conductor capacity. Siemens documentation lists all three articles in this family.

Difference from 2-Pole RCBO

The Siemens 5SU1354 and 5SU1624 families contain 2-pole RCBO configurations for compatible single-phase applications.

The 5SU1344-1RC32 is a 4-pole device intended for compatible three-phase-plus-neutral systems.

The pole configuration should therefore be checked carefully before selecting a replacement.

Difference Between RCBO and RCCB

The 5SU1344-1RC32 is an RCBO, not simply an RCCB.

An RCCB primarily provides residual-current protection and normally requires separate overcurrent protection.

An RCBO combines:

Residual-current protection + overload protection + short-circuit protection

in one device.

Suitable for Electrical Panel Builders and Industrial Buyers

The Siemens 5SU1344-1RC32 is relevant for:

  • Electrical panel builders

  • Industrial buyers

  • Electrical contractors

  • OEMs

  • Machine builders

  • Factory maintenance teams

  • Commercial electrical contractors

  • Electrical distributors

  • Automation system integrators

  • Electrical product dealers

For SB Smart, the product is positioned as a Siemens SENTRON / Betagard 5SU1 Type AC RCBO for 32 A three-phase circuit protection with C characteristic and 30 mA sensitivity.

These specifications are based on the current technical data for the exact 5SU1344-1RC32 article.

Key Features

  • Siemens SENTRON / Betagard 5SU1 RCBO

  • Article number 5SU1344-1RC32

  • 32 A rated current

  • 4-pole configuration

  • 8-module product designation

  • 7 modular width units in the technical data

  • Type AC residual-current protection

  • 30 mA residual-current sensitivity

  • C tripping characteristic

  • 415 V AC rated voltage

  • 50 Hz operating frequency

  • 10 kA EN 61009-1 short-circuit breaking capacity

  • 15 kA IEC 60947-2 switching capacity

  • 10 kA residual switching capacity

  • 440 V insulation voltage

  • 4 kV surge-voltage resistance

  • Neutral conductor switching

  • Top or bottom power-supply connection

  • Integrated overload and short-circuit protection

  • Integrated residual-current protection

  • Suitable for compatible three-phase-plus-neutral circuits

Benefits

  • Combined protection: Integrates overload, short-circuit and residual-current protection in one device.

  • 32 A rating: Suitable for compatible three-phase circuits and feeders.

  • Type AC protection: Designed for compatible sinusoidal AC residual currents.

  • 30 mA sensitivity: Provides residual-current protection at the specified operating threshold.

  • C characteristic: Suitable for compatible loads with moderate inrush current.

  • 4-pole construction: Suitable for compatible three-phase-plus-neutral systems.

  • Compact modular construction: Suitable for distribution boards and electrical panels.

  • 10 kA breaking capacity: Provides substantial short-circuit interruption capability within specified conditions.

  • Neutral switching: Supports the four-pole circuit arrangement.

  • Flexible supply connection: Power can be connected from the top or bottom.

Why Choose Siemens 5SU1344-1RC32?

The Siemens 5SU1344-1RC32 combines 32 A overcurrent protection, C-curve tripping and Type AC 30 mA residual-current protection in a four-pole RCBO.

The exact Siemens technical data confirms 415 V AC, 50 Hz, 32 A, 4-pole configuration, Type AC, 30 mA sensitivity, C characteristic and 10 kA EN 61009-1 short-circuit breaking capacity.

For SB Smart, this product is best presented as a Siemens Betagard/SENTRON 5SU1 Type AC RCBO for 32 A, 30 mA three-phase circuit protection with C characteristic across India.

The country-use warning should remain visible on the product page because Siemens explicitly states that use of these devices is not permitted in all countries and national installation regulations must be observed.

Delivery Across India

SB Smart supplies Siemens SENTRON/Betagard RCBOs, RCCBs and industrial electrical protection products across Faridabad, Gurgaon/Gurugram, Delhi NCR, Haryana, Noida, Punjab, Mumbai and other major Indian cities.

Frequently Asked Questions

1. What is Siemens 5SU1344-1RC32?

The 5SU1344-1RC32 is a Siemens SENTRON / Betagard 5SU1 RCBO rated at 32 A, with 4 poles, C characteristic, Type AC residual-current protection and 30 mA sensitivity.

2. Is this an RCBO or RCCB?

It is an RCBO, meaning it combines residual-current and overcurrent protection in one device.

3. What is the rated current?

The rated current is 32 A.

4. What is the residual-current sensitivity?

The rated residual operating current is 30 mA.

5. What type of residual-current protection does it use?

It uses Type AC residual-current protection.

6. What is the tripping characteristic?

It has a C tripping characteristic.

7. How many poles does it have?

It has 4 poles, suitable for compatible three-phase-plus-neutral applications.

8. What is the module width?

The product designation states 8 modules, while the technical data specifies 7 modular width units and a physical width of 126 mm.

9. What is the rated voltage?

The exact Siemens technical data specifies 415 V AC at 50 Hz.

10. What is the short-circuit breaking capacity?

The specified short-circuit breaking capacity is 10 kA according to EN 61009-1, with 15 kA according to IEC 60947-2 for the applicable switching-capacity specification.

11. Is this product permitted in every country?

No. Siemens explicitly states that use of these devices is not permitted in all countries and that national installation regulations must be observed.

12. What is the difference between 5SU1344-1RC32 and 5SU1344-7RC32?

5SU1344-1RC32: 32 A, 4-pole, Type AC, 30 mA, C characteristic.

5SU1344-7RC32: 32 A, 4-pole, Type A, 30 mA, C characteristic.

The main difference is the residual-current type. Siemens documentation lists both articles.

13. What is the difference between 5SU1344-1RC32 and 5SU1644-1RC32?

5SU1344-1RC32: 32 A, Type AC, 30 mA, C characteristic.

5SU1644-1RC32: 32 A, Type AC, 300 mA, C characteristic.

The main difference is the residual-current sensitivity.

14. Where can I buy Siemens 5SU1344-1RC32 in India?

SB Smart supplies Siemens SENTRON/Betagard 5SU1 RCBOs and industrial electrical protection products in India for panel builders, electrical contractors, OEMs, industrial buyers, machine builders and maintenance requirements.

Technical Specifications

Parameter

Specification

Product Series

Siemens Betagard 5SU1

Part Number

5SU1344-1RC32

Product Type

RCBO

Poles

4P

Rated Current

32A

Tripping Curve

C Curve

Residual Current

30 mA

Residual Type

AC

Rated Voltage

415V AC

Breaking Capacity

10 kA

Mounting Type

DIN Rail

Function

Overload + Short circuit + Earth leakage protection

Customer Reviews

Write a Review

No reviews yet.

Why Buy From SB Smart?

Authorized Supplier
Genuine products directly from manufacturers with warranty support.
Industrial Expertise
Over 10 years of experience in industrial automation and electricals.
PAN India Delivery
Fast and secure shipping to all major industrial hubs across India.
Dedicated Support
Expert technical team available for product selection and support.

Request a Quote

×
Product: Product Name

Thank You!

Your quote request has been submitted successfully.

Our team will contact you shortly.

Product Enquiry

×
Enquiring for: Product Name

Enquiry Sent!

We have received your enquiry.

Our team will get back to you soon.